BUY TL084ACD https://www.utsource.net/itm/p/11682604.html
IC OPAMP JFET 4 CIRCUIT 14SOIC

Below is the parameter table and instructions for the TL084ACD, a quad JFET-input operational amplifier.

TL084ACD Parameter Table

Parameter Symbol Min Typical Max Unit Conditions
Supply Voltage Range VCC 4.5 - 16 V ±2.25 to ±8V (Dual)
Input Offset Voltage VIO - 5 15 mV VCC = ±15V
Input Bias Current IB - 70 200 nA VCC = ±15V
Input Offset Current IOS - 5 20 nA VCC = ±15V
Open Loop Voltage Gain AVOL - 300 - V/mV VCC = ±15V
Slew Rate SR - 13 - V/μs VCC = ±15V
Output Voltage Swing VOUT -13 - 13 V VCC = ±15V
Power Consumption Ptot - 20 - mW VCC = ±15V
Common Mode Rejection Ratio CMRR - 86 - dB VCC = ±15V
Power Supply Rejection Ratio PSRR - 86 - dB VCC = ±15V
Equivalent Input Noise Voltage en - 18 - nV/√Hz VCC = ±15V, f = 1kHz
Bandwidth (Unity Gain) fT - 3.5 - MHz VCC = ±15V

Instructions for Using TL084ACD

  1. Supply Voltage:

    • The TL084ACD can operate with a supply voltage range of ±2.25V to ±8V (dual supply) or 4.5V to 16V (single supply).
    • Ensure the supply voltage is within the specified range to avoid damage to the device.
  2. Input Signals:

    • The input signals should be within the common mode input voltage range, which is typically from 3V below the negative supply to 3V below the positive supply.
    • Avoid exceeding the maximum differential input voltage, which is ±10V.
  3. Output Load:

    • The output can drive a load resistance of 2kΩ or greater.
    • For lower load resistances, ensure the output current does not exceed the maximum rating of 10mA.
  4. Powering the Device:

    • Connect the positive supply to pin 8 and the negative supply to pin 4.
    • Ground the unused pins if they are not being used in your circuit to avoid floating inputs.
  5. Stability:

    • The TL084ACD is unity-gain stable, but for optimal performance, use external compensation components if necessary.
    • Use capacitors to filter the power supply lines to reduce noise and improve stability.
  6. Temperature Considerations:

    • The operating temperature range is -40°C to +85°C.
    • Ensure proper heat dissipation if the device is operating at high temperatures or high power levels.
  7. Handling:

    • Handle the device with care to avoid static damage.
    • Follow standard ESD (Electrostatic Discharge) precautions when handling the device.
  8. Testing:

    • Before finalizing the design, test the circuit under various conditions to ensure it meets the desired performance specifications.
    • Use a breadboard or prototype board for initial testing before moving to a PCB.

By following these parameters and instructions, you can effectively integrate the TL084ACD into your analog circuits.

(For reference only)

View more about TL084ACD on main site