SN74HC4040N

SN74HC4040N


Specifications
SKU
11690948
Details

BUY SN74HC4040N https://www.utsource.net/itm/p/11690948.html
IC ASYNC BINARY COUNTER 16-DIP
Parameter Symbol Min Typical Max Unit Notes
Supply Voltage VCC 2.0 - 6.0 V
Input Voltage (High) VIH 3.15 - VCC V
Input Voltage (Low) VIL 0 - 1.35 V
Output Voltage (High) VOH VCC - 0.1 - VCC - 0.5 V
Output Voltage (Low) VOL 0 - 0.2 V
Input Current (High) IIH - - 1.0 μA
Input Current (Low) IIL -1.0 - - μA
Output Current (Source) IOH - - 25 mA
Output Current (Sink) IOL -25 - - mA
Propagation Delay Time tpd - 28 70 ns @ VCC = 4.5V, f = 1 MHz
Power Consumption Ptot - - 100 mW @ TA = 25°C

Instructions for Use

  1. Power Supply:

    • Connect VCC to the positive supply voltage (2.0V to 6.0V).
    • Connect GND to the ground.
  2. Reset (MR):

    • Apply a high level to MR to reset all flip-flops to the zero state.
    • MR should be held low during normal operation to allow counting.
  3. Clock Input (CP):

    • Apply the clock signal to the CP input.
    • The device will count on the rising edge of the clock signal.
  4. Clock Inhibit (CPI):

    • Apply a high level to CPI to inhibit the clock input.
    • CPI should be held low during normal operation to allow the clock to function.
  5. Outputs (Q0 to Q11):

    • The outputs Q0 to Q11 represent the binary count from 0 to 2047 (11-bit counter).
  6. Output Load:

    • Ensure that the output current does not exceed the maximum ratings (25mA source/sink per output).
  7. Decoupling Capacitors:

    • Place a 0.1μF decoupling capacitor close to the VCC and GND pins to filter out noise and stabilize the power supply.
  8. Operating Temperature:

    • The device is specified to operate over the temperature range of -40°C to +85°C.
  9. Storage Temperature:

    • Store the device in a dry environment with a temperature range of -65°C to +150°C.
  10. Handling Precautions:

    • Handle the device with care to avoid static damage.
    • Use proper ESD protection when handling the device.
  11. Soldering:

    • Follow standard soldering practices to ensure reliable connections.
    • Do not exceed the maximum soldering temperature of 260°C for more than 10 seconds.

By following these instructions, you can ensure the proper operation and longevity of the SN74HC4040N.