Details
BUY CD74HCT259E https://www.utsource.net/itm/p/11691058.html
IC 8BIT ADDRESSABLE LATCH 16-DIP
Parameter | Symbol | Min | Typ | Max | Unit | Description |
---|---|---|---|---|---|---|
Supply Voltage | VCC | 2.0 | 4.5 | 6.0 | V | Operating supply voltage |
Input Voltage (High) | VIH | 3.15 | - | VCC | V | Minimum input voltage for logic high |
Input Voltage (Low) | VIL | 0 | - | 0.8 | V | Maximum input voltage for logic low |
Output Voltage (High) | VOH | 2.4 | - | VCC - 0.5 | V | Minimum output voltage for logic high |
Output Voltage (Low) | VOL | 0 | - | 0.4 | V | Maximum output voltage for logic low |
Input Current (High) | IIH | - | 1.0 | 20 | μA | Input current at logic high |
Input Current (Low) | IIL | -1.0 | - | -20 | μA | Input current at logic low |
Output Current (Source) | IOH | - | 4.0 | 20 | mA | Maximum output current when sourcing |
Output Current (Sink) | IOL | -20 | -4.0 | - | mA | Maximum output current when sinking |
Propagation Delay Time | tpd | - | 18 | 36 | ns | Typical propagation delay time |
Power Dissipation | PD | - | - | 500 | mW | Maximum power dissipation |
Operating Temperature | TA | -40 | - | 85 | °C | Ambient operating temperature range |
Storage Temperature | TSTG | -65 | - | 150 | °C | Storage temperature range |
Instructions for Using the CD74HCT259E
Power Supply:
- Connect the VCC pin to a supply voltage between 2.0V and 6.0V.
- Connect the GND pin to ground.
Input Signals:
- Ensure that all input signals (e.g., A, B, C, G, E) are within the specified voltage ranges for logic high and low.
- Use appropriate pull-up or pull-down resistors if necessary to ensure stable logic levels.
Output Handling:
- The outputs can source or sink up to 20mA. Ensure that connected loads do not exceed this limit.
- Use external current-limiting resistors if driving LEDs or other components that require current limiting.
Propagation Delay:
- Account for the typical propagation delay of 18ns to 36ns when designing timing-sensitive circuits.
Thermal Management:
- Ensure adequate heat dissipation if the device is operating near its maximum power dissipation limit.
- Avoid exceeding the maximum operating temperature of 85°C.
Storage and Handling:
- Store the device in a dry environment within the storage temperature range of -65°C to 150°C.
- Handle with care to avoid static damage and mechanical stress.
Testing and Debugging:
- Use a multimeter to verify supply voltages and logic levels.
- Use an oscilloscope to measure propagation delays and signal integrity.
By following these guidelines, you can ensure reliable operation of the CD74HCT259E in your digital circuits.
(For reference only)View more about CD74HCT259E on main site