CD74HCT245E

CD74HCT245E

Category: IC Chips

Specifications
SKU
11694192
Details

BUY CD74HCT245E https://www.utsource.net/itm/p/11694192.html
IC TXRX NON-INVERT 5.5V 20DIP
Parameter Symbol Conditions Min Typical Max Unit
Supply Voltage VCC Continuous Operating Range 2.0 - 6.0 V
Input Voltage (Low) VIL VCC = 4.5V to 5.5V -0.5 - 1.5 V
Input Voltage (High) VIH VCC = 4.5V to 5.5V 3.5 - VCC + 0.5 V
Output Voltage (Low) VOL IOL = 25mA, VCC = 4.5V to 5.5V 0.0 - 0.4 V
Output Voltage (High) VOH IOH = -25mA, VCC = 4.5V to 5.5V VCC - 0.4 - VCC V
Input Leakage Current IIL VCC = 4.5V to 5.5V -1.0 - 1.0 μA
Output Leakage Current IOL VCC = 4.5V to 5.5V -1.0 - 1.0 μA
Propagation Delay Time tpd VCC = 5V, TA = 25°C - 8.0 18.0 ns
Power Dissipation PD Maximum at TA = 70°C - - 390 mW
Operating Temperature Range TA - -40 - 85 °C
Storage Temperature Range TSTG - -65 - 150 °C

Instructions for Using CD74HCT245E:

  1. Power Supply:

    • Ensure the supply voltage (VCC) is within the range of 2.0V to 6.0V.
    • Connect VCC to the positive power supply and GND to the ground.
  2. Input Signals:

    • Apply input signals (VIL and VIH) within the specified voltage ranges.
    • Ensure that the input signals do not exceed the supply voltage plus 0.5V or go below -0.5V to avoid damage.
  3. Output Signals:

    • The output signals (VOL and VOH) will be within the specified voltage ranges depending on the load current.
    • Ensure that the output current does not exceed the maximum ratings to avoid overheating and damage.
  4. Propagation Delay:

    • The propagation delay time (tpd) is crucial for timing considerations in your circuit. It should be considered when designing the system to ensure proper operation.
  5. Temperature Considerations:

    • Operate the device within the specified temperature range (-40°C to 85°C) for reliable performance.
    • Store the device within the storage temperature range (-65°C to 150°C).
  6. Handling:

    • Handle the device with care to avoid static discharge, which can damage the internal components.
    • Use appropriate ESD protection measures during handling and installation.
  7. Mounting:

    • Mount the device on a suitable PCB with proper heat dissipation if necessary.
    • Follow the recommended PCB layout guidelines to ensure optimal performance and reliability.
  8. Testing:

    • Test the device under the specified conditions to verify its functionality.
    • Use a multimeter or oscilloscope to check the input and output voltages and currents.

By following these parameters and instructions, you can ensure the proper and safe operation of the CD74HCT245E.

(For reference only)

View more about CD74HCT245E on main site