ADG406BN

ADG406BN


Specifications
SKU
11712836
Details

BUY ADG406BN https://www.utsource.net/itm/p/11712836.html
IC MULTIPLEXER 16X1 28DIP
Parameter Symbol Min Typ Max Unit Description
Supply Voltage VDD 2.7 - 5.5 V Operating supply voltage range
Quiescent Current IQ - 1.2 - mA Supply current at VDD = 5V, all channels off
Channel-to-Channel Isolation - - 80 - dB Isolation between channels at 1 MHz
On-State Resistance RON 20 30 40 Ω Maximum on-state resistance per channel at VDD = 5V, TA = 25°C
Leakage Current ILEAK - ±1 - μA Maximum leakage current per channel at VDD = 5V, TA = 25°C
Input Signal Range VIN -0.3 - VDD + 0.3 V Input signal range for analog signals
Switching Time tSW 1 - 10 μs Time to switch from off to on state
Operating Temperature TA -40 - 85 °C Ambient operating temperature range
Storage Temperature TSTG -65 - 150 °C Storage temperature range

Instructions for Use:

  1. Power Supply:

    • Ensure the supply voltage (VDD) is within the specified range of 2.7V to 5.5V.
    • Connect the ground (GND) pin to the system ground.
  2. Channel Control:

    • The ADG406BN is controlled by digital inputs (S0, S1, S2) to select one of the six channels.
    • Set the digital inputs to the appropriate binary values to activate the desired channel.
  3. Signal Handling:

    • Analog signals should be within the input signal range (-0.3V to VDD + 0.3V).
    • Ensure that the signal does not exceed these limits to avoid damage to the device.
  4. Thermal Management:

    • Operate the device within the ambient temperature range of -40°C to 85°C.
    • For extended storage, ensure temperatures do not fall below -65°C or rise above 150°C.
  5. Electrical Characteristics:

    • Monitor the quiescent current (IQ) to ensure it remains within the typical value of 1.2mA.
    • Check the on-state resistance (RON) to ensure it is within the specified range for optimal performance.
  6. Handling and Installation:

    • Handle the device with care to avoid static discharge, which can damage sensitive components.
    • Follow proper soldering techniques to ensure reliable connections and prevent thermal stress.
  7. Testing:

    • After installation, test the device by applying known signals to the selected channels and verifying the output.
    • Measure the leakage current (ILEAK) to ensure it is within the specified limits.

By following these instructions, you can ensure the ADG406BN operates reliably and efficiently in your application.

(For reference only)

View more about ADG406BN on main site