| Parameter | Symbol | Min | Typ | Max | Unit | Description |
|---|---|---|---|---|---|---|
| Input Voltage | V_IN | 2.7 | - | 5.5 | V | Operating input voltage range |
| Output Voltage | V_OUT | - | 3.3 | - | V | Fixed output voltage |
| Output Current | I_OUT | - | 200 | - | mA | Continuous output current |
| Quiescent Current | I_Q | - | 1.5 | - | μA | Current consumption in active mode |
| Shutdown Current | I_SD | - | 0.1 | - | μA | Current consumption in shutdown mode |
| Dropout Voltage | V_DO | - | 200 | - | mV | Voltage difference between V_IN and V_OUT |
| Load Regulation | - | - | 0.5 | - | % | Change in output voltage with load |
| Line Regulation | - | - | 0.1 | - | %/V | Change in output voltage with input voltage |
| Thermal Shutdown | T_SHD | - | 160 | - | °C | Temperature at which the device shuts down |
| Operating Temperature | T_OP | -40 | - | 85 | °C | Ambient temperature range for operation |
| Storage Temperature | T_STG | -65 | - | 150 | °C | Temperature range for storage |
Instructions for Use:
Power Supply Connection:
- Connect the input voltage (V_IN) to the positive terminal of the power supply.
- Ensure the input voltage is within the specified range (2.7V to 5.5V).
Output Connection:
- Connect the output voltage (V_OUT) to the load or circuit requiring a stable 3.3V supply.
- The maximum continuous output current is 200mA.
Ground Connection:
- Connect the ground (GND) pin to the common ground of the system.
Shutdown Pin:
- To put the device into shutdown mode, connect the shutdown (SD) pin to ground (GND).
- To activate the device, leave the SD pin open or connect it to V_IN.
Capacitors:
- Place a 1μF ceramic capacitor close to the input (V_IN) and output (V_OUT) pins to ensure stability.
- Additional capacitors may be required depending on the specific application and load characteristics.
Thermal Management:
- Ensure adequate heat dissipation if operating at high currents or in high ambient temperatures.
- The device will automatically shut down if the junction temperature exceeds 160°C.
Storage and Handling:
- Store the device in a dry environment within the temperature range of -65°C to 150°C.
- Handle the device with care to avoid damage from electrostatic discharge (ESD).
Testing:
- Before finalizing the design, test the device under various operating conditions to ensure it meets the required performance specifications.
Compliance:
- Ensure that the device is used in compliance with all relevant safety and regulatory standards.