LM336Z5

LM336Z5


Specifications
SKU
11716078
Details

BUY LM336Z5 https://www.utsource.net/itm/p/11716078.html
IC VREF SHUNT 5V TO92-3
Parameter Symbol Conditions Min Typical Max Unit
Output Voltage VOUT IO = 10 mA - 5.0 - V
Line Regulation ΔVOUT/ΔIL IL = 0 to 15 mA - 0.005 - %/mA
Load Regulation ΔVOUT/ΔIL IL = 1 to 15 mA - 0.005 - %/mA
Temperature Coefficient TC IO = 10 mA, TA = -55 to 125°C - 100 - ppm/°C
Output Impedance ZOUT IO = 10 mA - 100 - Ω
Operating Current IOP - 0.1 1.0 10 mA
Storage Temperature Range TSTG - -65 - 150 °C

Instructions for Using LM336Z5

  1. Circuit Configuration:

    • The LM336Z5 is a precision shunt voltage reference designed to provide a stable 5.0V output.
    • Connect the device in parallel with the load to maintain a constant voltage across the load.
  2. Biasing Current:

    • Ensure that the biasing current (IO) is within the range of 0.1 mA to 10 mA for optimal performance.
    • A typical value of 10 mA is recommended for best stability and accuracy.
  3. Capacitor Requirements:

    • For improved stability and noise reduction, it is recommended to place a 1 μF capacitor in parallel with the LM336Z5.
    • Place the capacitor as close as possible to the device to minimize parasitic inductance.
  4. Thermal Considerations:

    • The device should be mounted on a heatsink if it is expected to dissipate significant power.
    • Ensure that the operating temperature does not exceed 150°C to avoid damage to the device.
  5. Power Supply:

    • The input voltage should be at least 1.5V higher than the output voltage (5.0V) to ensure proper operation.
    • The maximum input voltage is limited by the power dissipation capability of the device.
  6. Storage and Handling:

    • Store the device in a dry, cool environment to prevent moisture damage.
    • Handle the device with care to avoid static discharge, which can damage the internal circuitry.
  7. Testing:

    • Before integrating the LM336Z5 into a circuit, test the device to ensure it meets the specified output voltage and stability requirements.
    • Use a multimeter to measure the output voltage under various load conditions to verify performance.

By following these instructions, you can ensure reliable and accurate operation of the LM336Z5 in your application.

(For reference only)

View more about LM336Z5 on main site