TJA1040T/CM,118

TJA1040T/CM,118


Specifications
SKU
11719787
Details

BUY TJA1040T/CM,118 https://www.utsource.net/itm/p/11719787.html
IC TRANSCEIVER HALF 1/1 8SO
Parameter Symbol Min Typical Max Unit Conditions
Supply Voltage VCC 3.0 - 5.5 V -
Quiescent Current ICC - 1.2 - mA VCC = 5V, no load
Output Current IO - - 40 mA Continuous, VCC = 5V
Differential Input Voltage Range VID -2 - 12 V -
Common-Mode Input Voltage Range VICM -2 - 14 V -
Input Offset Voltage VOS -0.5 0 0.5 mV VCC = 5V
Slew Rate SR - 1.0 - V/μs VCC = 5V
Operating Temperature Range TOP -40 - 125 °C -
Storage Temperature Range TSTG -65 - 150 °C -

Instructions for TJA1040T/CM,118

  1. Power Supply:

    • Ensure the supply voltage (VCC) is within the range of 3.0V to 5.5V.
    • Use a stable power supply to avoid fluctuations that can affect performance.
  2. Quiescent Current:

    • The quiescent current is typically 1.2mA at 5V. Ensure your power supply can handle this current without significant voltage drop.
  3. Output Current:

    • The maximum continuous output current is 40mA. Do not exceed this limit to prevent damage to the device.
  4. Differential and Common-Mode Input Voltage:

    • The differential input voltage range is -2V to 12V, and the common-mode input voltage range is -2V to 14V. Ensure input signals stay within these ranges to avoid distortion or damage.
  5. Input Offset Voltage:

    • The input offset voltage is ±0.5mV at 5V supply. This should be considered when designing circuits that require high precision.
  6. Slew Rate:

    • The slew rate is 1.0V/μs. This is important for applications involving fast-changing signals to ensure accurate signal reproduction.
  7. Operating and Storage Temperature:

    • The operating temperature range is -40°C to 125°C, and the storage temperature range is -65°C to 150°C. Ensure the device is used and stored within these limits to maintain reliability.
  8. Handling and Installation:

    • Handle the device with care to avoid static discharge and physical damage.
    • Follow proper soldering techniques to ensure reliable connections and prevent thermal damage during installation.
  9. Testing and Troubleshooting:

    • Regularly test the device to ensure it is functioning within specified parameters.
    • If issues arise, check for power supply stability, correct input signal levels, and proper connections.
  10. Compliance and Standards:

    • Ensure the device complies with relevant industry standards and regulations for your specific application.
(For reference only)

View more about TJA1040T/CM,118 on main site