Parameter Symbol Min Typ Max Unit Description
Supply Voltage Vcc 4.5 5 5.5 V Operating voltage range for the device.
Output Current Iout - 100 150 mA Maximum continuous output current.
Quiescent Current Iq - 0.5 1 mA Current consumed by the device when no load is present.
Dropout Voltage Vdo - 0.3 0.6 V Voltage difference between input and output at which regulation is lost.
Line Regulation ΔVout/ΔVin - 0.01 0.02 %/V Change in output voltage per unit change in input voltage.
Load Regulation ΔVout/ΔIout - 0.01 0.02 %/mA Change in output voltage per unit change in output current.
Ripple Rejection RR - 60 80 dB Ability to reject ripple from the input voltage.
Operating Temperature Toper -40 - 125 °C Temperature range over which the device can operate reliably.
Storage Temperature Tstg -65 - 150 °C Temperature range over which the device can be stored without damage.

Instructions for Using N82077SL:

  1. Power Supply Connection:

    • Connect the input (VIN) to the positive terminal of your power supply.
    • Connect the ground (GND) to the negative terminal of your power supply.
  2. Output Connection:

    • Connect the output (VOUT) to the load or circuit that requires regulated power.
  3. Capacitors:

    • Place a 10 μF electrolytic capacitor between VIN and GND close to the device to stabilize the input voltage.
    • Place a 1 μF ceramic capacitor between VOUT and GND to stabilize the output voltage.
  4. Heat Dissipation:

    • Ensure adequate heat dissipation if operating at high output currents or in high ambient temperatures. Consider using a heatsink if necessary.
  5. Input Voltage:

    • Ensure the input voltage is within the specified range (4.5 V to 5.5 V) to avoid damage to the device.
  6. Output Current:

    • Do not exceed the maximum output current (150 mA) to prevent overheating and potential damage.
  7. Storage and Handling:

    • Store the device in a dry, cool place within the specified storage temperature range (-65°C to 150°C).
    • Handle with care to avoid static discharge, which can damage the device.
  8. Testing:

    • Before connecting the device to your final application, test it on a breadboard or prototype board to ensure it meets your requirements.
  9. Compliance:

    • Ensure the device complies with all relevant safety and regulatory standards for your application.