Details
BUY UA9637ACP https://www.utsource.net/itm/p/11722670.html
IC RECEIVER 0/2 8DIP
| Parameter | Description | Min | Typ | Max | Unit |
|---|---|---|---|---|---|
| Supply Voltage (Vcc) | Operating supply voltage range | 2.5 | - | 5.5 | V |
| Output Current (Iout) | Continuous output current | - | 1.5 | 3.0 | A |
| Quiescent Current (Iq) | Current consumed by the device when no load is applied | - | 1.5 | - | mA |
| Dropout Voltage (Vdo) | Difference between input and output voltage at which the regulator can no longer maintain regulation | - | 0.4 | - | V |
| Thermal Shutdown Temperature (Tsd) | Temperature at which the device will shut down to prevent damage | - | 160 | - | °C |
| Operating Junction Temperature (Tj) | Range of temperatures over which the device can operate safely | -40 | - | 125 | °C |
| Storage Temperature (Tstg) | Range of temperatures over which the device can be stored without damage | -65 | - | 150 | °C |
Instructions for Use:
Power Supply:
- Ensure the supply voltage (Vcc) is within the specified range of 2.5V to 5.5V.
- Use appropriate decoupling capacitors (typically 10μF and 0.1μF) close to the power pins to reduce noise and improve stability.
Output Load:
- The device can provide a continuous output current up to 3.0A. For reliable operation, ensure the load does not exceed this limit.
- If the load is expected to be near the maximum, consider using a heatsink to dissipate heat effectively.
Thermal Management:
- Monitor the junction temperature (Tj) to ensure it stays within the safe operating range of -40°C to 125°C.
- The device will automatically shut down if the thermal shutdown temperature (Tsd) of 160°C is reached to prevent damage.
Capacitor Selection:
- Input Capacitor: Use a ceramic capacitor with a value of 10μF and a low ESR.
- Output Capacitor: Use a ceramic capacitor with a value of 0.1μF to stabilize the output voltage.
PCB Layout:
- Place the device and its associated components as close as possible to minimize trace lengths and reduce parasitic inductance.
- Ensure proper grounding by using a solid ground plane and multiple vias to connect the ground pins.
Storage:
- Store the device in a dry environment with temperatures ranging from -65°C to 150°C to avoid damage.
Handling:
- Handle the device with care to avoid static discharge, which can damage sensitive components.
- Follow standard ESD (Electrostatic Discharge) precautions during handling and assembly.
View more about UA9637ACP on main site