TLP185(GB-TPL,E)

TLP185(GB-TPL,E)


Specifications
SKU
11737049
Details

BUY TLP185(GB-TPL,E) https://www.utsource.net/itm/p/11737049.html
You deserve it
Parameter Symbol Min Typ Max Unit Conditions
Forward Voltage VF - 1.2 1.6 V IF = 20 mA
Reverse Voltage VR - - 5 V -
Continuous Forward Current IF - - 50 mA Ta = 25°C
Peak Forward Current IF(surge) - - 100 mA t = 1 s, Ta = 25°C
Output Collector-Emitter Voltage VCEO - - 30 V IC = 50 mA, VR = 5 V
Output Collector Current IC - - 50 mA Ta = 25°C
CTR (Current Transfer Ratio) CTR 200 400 800 % IF = 5 mA, IC = 5 mA
Rise Time tr - 1.5 2.5 μs RL = 1 kΩ, CL = 100 pF
Fall Time tf - 1.5 2.5 μs RL = 1 kΩ, CL = 100 pF
Storage Temperature TSTG -40 - 110 °C -
Operating Temperature TOP -40 - 105 °C -

Instructions for Use:

  1. Mounting:

    • Ensure that the device is mounted on a PCB with appropriate soldering techniques.
    • Avoid excessive heat during soldering to prevent damage to the device.
  2. Electrical Connections:

    • Connect the anode and cathode leads correctly to avoid reverse bias conditions.
    • Ensure that the output collector and emitter leads are connected to the appropriate circuit nodes.
  3. Power Supply:

    • Do not exceed the maximum ratings for forward voltage, reverse voltage, and current.
    • Use appropriate current-limiting resistors to ensure the device operates within its safe operating area.
  4. Thermal Management:

    • Ensure adequate cooling if the device will be operated at high currents or in high ambient temperatures.
    • Refer to the thermal resistance data provided by the manufacturer for optimal heat dissipation.
  5. Storage and Handling:

    • Store the device in a dry, cool place away from direct sunlight.
    • Handle the device with care to avoid mechanical stress or damage to the leads.
  6. Testing:

    • Use a suitable test setup to verify the device parameters such as CTR, rise time, and fall time.
    • Ensure that the test conditions match the specified conditions in the datasheet.
  7. Safety:

    • Follow all safety guidelines when handling and testing the device.
    • Use appropriate protective equipment to prevent electrical shock or injury.

For detailed specifications and additional information, refer to the official datasheet provided by the manufacturer.

(For reference only)

View more about TLP185(GB-TPL,E) on main site