Details

BUY UCC28084DR https://www.utsource.net/itm/p/11741699.html

Parameter Symbol Min Typ Max Unit Description
Supply Voltage VCC 8.5 - 16 V Operating range of the supply voltage
Start-Up Current ISTART - 150 - 渭A Typical current required to start the device
Quiescent Current IQ - 200 - 渭A Typical quiescent current at nominal operating conditions
Oscillator Frequency fOSC 300 - 700 kHz Range of the internal oscillator frequency
Minimum On-Time tON(min) 250 - - ns Minimum on-time for the high-side switch
Maximum Off-Time tOFF(max) - - 1500 ns Maximum off-time for the high-side switch
Overcurrent Protection Threshold IFAULT - 1.2 - A Threshold for overcurrent protection
Thermal Shutdown Temperature TSD 150 - - 掳C Temperature at which thermal shutdown is initiated
Operating Temperature Range TOPR -40 - 125 掳C Range of ambient temperatures for operation
Storage Temperature Range TSTG -65 - 150 掳C Range of temperatures for storage

Instructions for Using UCC28084DR

  1. Supply Voltage (VCC):

    • Ensure the supply voltage is within the range of 8.5V to 16V to avoid damage to the device.
    • Use a stable power source to maintain consistent operation.
  2. Start-Up Current (ISTART):

    • The device requires a typical current of 150 渭A to start up. Ensure the power supply can provide this current.
  3. Quiescent Current (IQ):

    • The typical quiescent current is 200 渭A. This should be considered in power budget calculations.
  4. Oscillator Frequency (fOSC):

    • The internal oscillator frequency ranges from 300 kHz to 700 kHz. Adjust external components if needed to achieve the desired frequency.
  5. Minimum On-Time (tON(min)):

    • The minimum on-time for the high-side switch is 250 ns. Ensure the pulse width modulation (PWM) signals respect this limit.
  6. Maximum Off-Time (tOFF(max)):

    • The maximum off-time for the high-side switch is 1500 ns. This helps in preventing excessive duty cycles.
  7. Overcurrent Protection (IFault):

    • The device has an overcurrent protection threshold of 1.2 A. If the current exceeds this value, the device will shut down to protect itself.
  8. Thermal Shutdown (TSD):

    • The device will initiate thermal shutdown at 150掳C to prevent damage from overheating. Ensure proper heat dissipation and cooling mechanisms are in place.
  9. Operating Temperature Range (TOPR):

    • The device can operate in ambient temperatures ranging from -40掳C to 125掳C. Ensure the environment does not exceed these limits.
  10. Storage Temperature Range (TSTG):

    • The device can be stored in temperatures ranging from -65掳C to 150掳C. Proper storage conditions should be maintained to ensure long-term reliability.

Additional Notes:

  • Always refer to the datasheet for the most accurate and detailed information.
  • Ensure all connections are secure and follow good PCB layout practices to minimize noise and interference.
  • Test the device under various operating conditions to ensure it meets the design requirements.
(For reference only)

View more about UCC28084DR on main site