Details
BUY FFPF05U60STU https://www.utsource.net/itm/p/11745217.html
Parameter | Symbol | Min | Typ | Max | Unit | Notes |
---|---|---|---|---|---|---|
Rated Voltage | VRMS | - | 600 | - | V | Continuous RMS voltage |
Peak Repetitive Reverse Voltage | VRRM | - | 600 | - | V | Repetitive peak reverse voltage |
Average Rectified Output Current | IAV | - | 5 | - | A | Non-inductive load, TA = 25掳C |
Peak Recurrent Reverse Voltage | VRRP | - | 600 | - | V | Repetitive peak reverse voltage |
Peak Surge Current | ISM | - | 300 | - | A | tf = 8.3 ms, sin 1/2 wave, TC = 25掳C |
Forward Voltage Drop | VF | 0.7 | 1.0 | 1.2 | V | IF = 5 A, TJ = 25掳C |
Reverse Recovery Time | trr | - | 35 | - | ns | IF = 5 A, IR = 50 mA, TJ = 25掳C |
Junction Temperature | TJ | - | - | 150 | 掳C | Maximum operating junction temperature |
Storage Temperature | TSTG | -40 | - | 150 | 掳C | Storage temperature range |
Thermal Resistance (Junction to Case) | R胃JC | - | 1.5 | - | 掳C/W | Thermal resistance from junction to case |
Instructions for Use:
Mounting:
- Ensure proper heat sinking to maintain the junction temperature within the specified limits.
- Use a thermal compound between the device and the heat sink to improve thermal conductivity.
Electrical Connections:
- Connect the device according to the polarity markings on the package.
- Ensure that all connections are secure and free from shorts or open circuits.
Surge Handling:
- The device can handle surge currents up to 300 A for short durations (8.3 ms, sine half-wave). Ensure that the circuit design accounts for these conditions.
Reverse Voltage:
- The device is rated for a peak repetitive reverse voltage of 600 V. Ensure that the reverse voltage does not exceed this value to prevent damage.
Forward Current:
- The average rectified output current is 5 A at 25掳C. For higher ambient temperatures, derate the current to ensure reliable operation.
Thermal Management:
- Monitor the junction temperature to ensure it does not exceed 150掳C. Use appropriate cooling methods such as forced air or liquid cooling if necessary.
Storage:
- Store the device in a dry environment with temperatures between -40掳C and 150掳C to prevent damage.
Handling:
- Handle the device with care to avoid mechanical stress or damage to the leads.
- Follow ESD (Electrostatic Discharge) precautions to prevent damage from static electricity.