Parameter Description Value
Device Isolated CAN Transceiver with 卤58-V Fault Protection and 卤58-V Common-Mode Range ISO1042BDWVR
Package Wide Body SOIC (DBW) 16-Pin
Operating Voltage VCC1 (Power Supply for Logic Side) 3.3V to 5.5V
Operating Voltage VCC2 (Power Supply for Bus Side) 3.3V to 5.5V
Isolation Voltage VIORM (Reinforced Isolation) 5000Vrms
Data Rate Maximum Data Rate 500 kbps
Common-Mode Range Differential Input Common-Mode Range 卤58V
Fault Protection Overvoltage and Short-Circuit Protection on CANH and CANL 卤58V
Operating Temperature Ambient Operating Temperature Range -40掳C to 125掳C
Storage Temperature Storage Temperature Range -65掳C to 150掳C
ESD Protection Human Body Model (HBM) 卤8kV
Pin Configuration Pin 1: VCC1 (Logic Side Power)
Pin Configuration Pin 2: GND1 (Logic Side Ground)
Pin Configuration Pin 3: TXD (Transmit Data)
Pin Configuration Pin 4: RXD (Receive Data)
Pin Configuration Pin 5: STBY (Standby)
Pin Configuration Pin 6: NC (No Connect)
Pin Configuration Pin 7: NC (No Connect)
Pin Configuration Pin 8: NC (No Connect)
Pin Configuration Pin 9: NC (No Connect)
Pin Configuration Pin 10: NC (No Connect)
Pin Configuration Pin 11: NC (No Connect)
Pin Configuration Pin 12: VCC2 (Bus Side Power)
Pin Configuration Pin 13: GND2 (Bus Side Ground)
Pin Configuration Pin 14: CANH (CAN High)
Pin Configuration Pin 15: CANL (CAN Low)
Pin Configuration Pin 16: NC (No Connect)

Instructions:

  1. Power Supply: Ensure that both VCC1 (logic side) and VCC2 (bus side) are powered within the specified range (3.3V to 5.5V).
  2. Ground Connection: Connect GND1 (logic side ground) and GND2 (bus side ground) to their respective ground references.
  3. Data Lines: Connect TXD and RXD to the microcontroller or other logic device.
  4. CAN Bus Lines: Connect CANH and CANL to the CAN bus.
  5. Standby Mode: Set the STBY pin to high to enter standby mode, which reduces power consumption.
  6. Fault Protection: The device provides 卤58V fault protection on the CANH and CANL lines. Ensure that these lines are not exposed to voltages exceeding this range.
  7. Temperature Considerations: Operate the device within the specified ambient temperature range (-40掳C to 125掳C) to ensure reliable performance.
  8. ESD Handling: Handle the device with proper ESD precautions to avoid damage. The device has 卤8kV HBM ESD protection.
  9. Mounting: Use appropriate PCB layout and mounting techniques to ensure proper isolation and thermal management.
(For reference only)