NCP1012AP065G

NCP1012AP065G

Category: IC Chips

Specifications
Details

BUY NCP1012AP065G https://www.utsource.net/itm/p/11798541.html

Parameter Symbol Conditions Min Typ Max Unit
Input Voltage VIN Continuous Operating Range 2.7 - 5.5 V
Output Voltage VOUT Fixed Output - 3.3 - V
Quiescent Current IQ VIN = 5V, IOUT = 0mA - 60 - μA
Dropout Voltage VDROPOUT IOUT = 100mA - 300 - mV
Load Regulation ΔVOUT/ΔIOUT IOUT = 0mA to 100mA - 0.5 - %
Line Regulation ΔVOUT/ΔVIN VIN = 2.7V to 5.5V - 0.1 - %
Ripple Rejection RR f = 120Hz - 60 - dB
Operating Temperature Toper Storage -40 - 85 °C

Instructions for NCP1012AP065G:

  1. Input Voltage (VIN):

    • Ensure the input voltage is within the range of 2.7V to 5.5V for stable operation.
  2. Output Voltage (VOUT):

    • The device provides a fixed output voltage of 3.3V. No external components are required to set this voltage.
  3. Quiescent Current (IQ):

    • The quiescent current is typically 60μA at an input voltage of 5V with no load. This parameter helps in assessing power efficiency.
  4. Dropout Voltage (VDROPOUT):

    • The dropout voltage is typically 300mV at an output current of 100mA. Ensure the input voltage is sufficiently higher than the output voltage by at least this margin.
  5. Load Regulation:

    • Load regulation is specified as 0.5% from no load to full load conditions, ensuring minimal variation in output voltage with changing load currents.
  6. Line Regulation:

    • Line regulation is specified as 0.1% over the input voltage range, indicating stability of output voltage with changes in input voltage.
  7. Ripple Rejection:

    • The device offers 60dB ripple rejection at 120Hz, effectively filtering out input voltage noise.
  8. Operating Temperature:

    • The device can operate within the temperature range of -40°C to 85°C, suitable for a wide range of environmental conditions.
  9. Mounting and Handling:

    • Follow standard surface mount technology (SMT) procedures for mounting. Ensure proper thermal management if operating near the upper temperature limit.
  10. Protection Features:

    • The device includes internal protection features such as thermal shutdown and current limiting to prevent damage under fault conditions.
(For reference only)

View more about NCP1012AP065G on main site