Details
BUY MBRS2H100T3G https://www.utsource.net/itm/p/12353629.html
Parameter | Symbol | Min | Typ | Max | Unit | Condition |
---|---|---|---|---|---|---|
Average Rectified Output Current (Non-Repetitive) | IF(AV) | - | 2.0 | - | A | TA = 25掳C, f = 50/60 Hz, CL = 10 渭F |
Peak Repetitive Reverse Voltage | VRSM | - | - | 100 | V | TJ = 25掳C |
RMS Reverse Voltage | VRMS | - | - | 70.7 | V | - |
Forward Voltage at Rated Current | VF | - | 1.1 | - | V | IF = 2.0 A, TJ = 25掳C |
Peak Forward Surge Current (Non-Repetitive) | IFSM | - | 80 | - | A | tp = 8.3 ms, sinewave, TJ = 25掳C |
Junction Temperature Range | TJ | -55 | - | 175 | 掳C | - |
Storage Temperature Range | TSTG | -55 | - | 150 | 掳C | - |
Thermal Resistance, Junction to Case | R胃JC | - | 10 | - | 掳C/W | - |
Instructions for MBRS2H100T3G
Handling and Storage:
- Store the device in a dry, cool place to prevent moisture damage.
- Handle with care to avoid mechanical stress or damage to the leads.
Mounting:
- Ensure proper alignment of the leads during soldering to avoid misalignment and potential short circuits.
- Use a heat sink if necessary to manage thermal dissipation, especially under high current conditions.
Soldering:
- Soldering temperature should not exceed 260掳C for more than 10 seconds.
- Avoid excessive heating which can cause damage to the device.
Electrical Connections:
- Ensure that the polarity is correct when connecting the diode to the circuit. The cathode (bar) and anode (no bar) must be connected correctly.
- Use appropriate wire gauge to handle the rated current without excessive voltage drop.
Thermal Management:
- Monitor the junction temperature to ensure it stays within the specified range to prevent thermal runaway.
- If operating in high ambient temperatures, consider additional cooling methods such as forced air or heat sinks.
Surge Current Handling:
- The device can handle peak forward surge currents up to 80A for a short duration (8.3 ms). Ensure that any surge currents do not exceed this limit to avoid damage.
Reverse Voltage Protection:
- The maximum reverse voltage should not exceed 100V to prevent breakdown and potential failure of the diode.
Testing:
- Use a multimeter to verify the continuity and polarity of the diode before installation.
- Perform functional tests after installation to ensure the diode is operating correctly.
Compliance:
- Ensure that the device meets all relevant safety and compliance standards for your application.
Documentation:
- Refer to the datasheet for detailed specifications and additional information.
- Keep a record of the part number and batch for traceability and warranty purposes.
View more about MBRS2H100T3G on main site