Details
BUY IXYN100N65A3 https://www.utsource.net/itm/p/12357479.html
Parameter | Symbol | Value | Unit | Notes |
---|---|---|---|---|
Maximum Drain-Source Voltage | VDS(max) | 650 | V | Continuous |
Maximum Gate-Source Voltage | VGS(max) | ±20 | V | Continuous |
Maximum Drain Current (Tc = 25°C) | ID(max) | 100 | A | Pulse (10 μs, 1% duty cycle) |
Maximum Drain Current (Tc = 100°C) | ID(max) | 70 | A | Pulse (10 μs, 1% duty cycle) |
Maximum Power Dissipation (Tc = 25°C) | PTOT(max) | 300 | W | Continuous |
Maximum Junction Temperature | TJ(max) | 150 | °C | - |
Storage Temperature Range | TSTG | -55 to 150 | °C | - |
Thermal Resistance, Junction to Case | Rth(j-c) | 0.5 | K/W | - |
Total Gate Charge | QG | 180 | nC | VGS = 15 V, ID = 50 A |
Input Capacitance | Ciss | 4400 | pF | VDS = 650 V, f = 1 MHz |
Output Capacitance | Coss | 160 | pF | VDS = 650 V, f = 1 MHz |
Reverse Transfer Capacitance | Crss | 120 | pF | VDS = 650 V, f = 1 MHz |
Instructions for Use:
Handling and Storage:
- Store the device in a dry, cool place within the temperature range specified.
- Handle with care to avoid damage to the pins and body.
Mounting:
- Ensure proper heat sinking to maintain the junction temperature below the maximum limit.
- Use thermal paste or thermal interface material between the device and the heat sink for better thermal performance.
Electrical Connections:
- Apply gate voltage carefully to avoid exceeding the maximum gate-source voltage.
- Use short leads to minimize parasitic inductance and capacitance.
- Ensure the drain and source connections are secure and have low resistance.
Operating Conditions:
- Do not exceed the maximum ratings under any operating conditions.
- For continuous operation, ensure that the power dissipation does not exceed the rated value at the specified case temperature.
- Monitor the junction temperature to prevent overheating, which can lead to premature failure.
Testing and Troubleshooting:
- Use appropriate test equipment and methods to verify the device parameters.
- If the device fails to meet specifications, check for proper installation, correct voltage levels, and adequate cooling.
Safety Precautions:
- Always use appropriate safety gear when handling high-voltage circuits.
- Follow all local and international electrical safety standards and regulations.
View more about IXYN100N65A3 on main site