Parameter Symbol Value Unit Notes
Maximum Drain-Source Voltage VDS(max) 650 V Continuous
Maximum Gate-Source Voltage VGS(max) ±20 V Continuous
Maximum Drain Current (Tc = 25°C) ID(max) 100 A Pulse (10 μs, 1% duty cycle)
Maximum Drain Current (Tc = 100°C) ID(max) 70 A Pulse (10 μs, 1% duty cycle)
Maximum Power Dissipation (Tc = 25°C) PTOT(max) 300 W Continuous
Maximum Junction Temperature TJ(max) 150 °C -
Storage Temperature Range TSTG -55 to 150 °C -
Thermal Resistance, Junction to Case Rth(j-c) 0.5 K/W -
Total Gate Charge QG 180 nC VGS = 15 V, ID = 50 A
Input Capacitance Ciss 4400 pF VDS = 650 V, f = 1 MHz
Output Capacitance Coss 160 pF VDS = 650 V, f = 1 MHz
Reverse Transfer Capacitance Crss 120 pF VDS = 650 V, f = 1 MHz

Instructions for Use:

  1. Handling and Storage:

    • Store the device in a dry, cool place within the temperature range specified.
    • Handle with care to avoid damage to the pins and body.
  2. Mounting:

    • Ensure proper heat sinking to maintain the junction temperature below the maximum limit.
    • Use thermal paste or thermal interface material between the device and the heat sink for better thermal performance.
  3. Electrical Connections:

    • Apply gate voltage carefully to avoid exceeding the maximum gate-source voltage.
    • Use short leads to minimize parasitic inductance and capacitance.
    • Ensure the drain and source connections are secure and have low resistance.
  4. Operating Conditions:

    • Do not exceed the maximum ratings under any operating conditions.
    • For continuous operation, ensure that the power dissipation does not exceed the rated value at the specified case temperature.
    • Monitor the junction temperature to prevent overheating, which can lead to premature failure.
  5. Testing and Troubleshooting:

    • Use appropriate test equipment and methods to verify the device parameters.
    • If the device fails to meet specifications, check for proper installation, correct voltage levels, and adequate cooling.
  6. Safety Precautions:

    • Always use appropriate safety gear when handling high-voltage circuits.
    • Follow all local and international electrical safety standards and regulations.