Details
BUY L6571B https://www.utsource.net/itm/p/12360110.html
| Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
|---|---|---|---|---|---|---|
| Supply Voltage | VCC | Operating | 16.5 | - | 30 | V |
| Start-Up Current | IST | 2 | - | 8 | mA | |
| Quiescent Current | IQ | No load | 4 | - | 7 | mA |
| Oscillator Frequency | fosc | RT = 100 kΩ, CT = 22 pF | 25 | 50 | 100 | kHz |
| Maximum Duty Cycle | DMAX | 90 | - | - | % | |
| Minimum On-Time | tonmin | 1.8 | - | - | μs | |
| Minimum Off-Time | toffmin | 1.8 | - | - | μs | |
| Overcurrent Protection | ICP | Threshold | 0.8 | - | 1.2 | V |
| Thermal Shutdown | TSD | 160 | - | - | °C |
Instructions for L6571B
Supply Voltage (VCC):
- Ensure the supply voltage is within the range of 16.5V to 30V for proper operation.
Start-Up Current (IST):
- The start-up current should be between 2mA and 8mA. This ensures the device initializes correctly without excessive power draw.
Quiescent Current (IQ):
- When no load is present, the quiescent current should remain between 4mA and 7mA to minimize power consumption.
Oscillator Frequency (fosc):
- Set the oscillator frequency using external resistor (RT) and capacitor (CT). For typical applications, use RT = 100 kΩ and CT = 22 pF to achieve a frequency range of 25kHz to 100kHz.
Maximum Duty Cycle (DMAX):
- Limit the duty cycle to a maximum of 90% to prevent overdriving the output stage.
Minimum On-Time (tonmin) and Minimum Off-Time (toffmin):
- Ensure that the minimum on-time and off-time are both at least 1.8μs to avoid instability in switching operations.
Overcurrent Protection (ICP):
- The overcurrent protection threshold is set between 0.8V and 1.2V. Monitor this parameter to protect against excessive current conditions.
Thermal Shutdown (TSD):
- The device will initiate thermal shutdown if the temperature exceeds 160°C. Design adequate heat dissipation to prevent this from occurring under normal operating conditions.
View more about L6571B on main site