Details

BUY MAX392CSE+T https://www.utsource.net/itm/p/12368912.html

Parameter Symbol Conditions Min Typ Max Unit
Supply Voltage VCC Operating 4.5 - 5.5 V
Input Voltage Range VIN -0.3 - VCC+0.3 V
Output Voltage Range VOUT High Level VCC-2.7 - VCC-0.8 V
VOUT Low Level 0 - 0.8 V
Power Dissipation PD Maximum - - 160 mW
Operating Temperature Toper Junction -40 - 85 °C
Storage Temperature Tstg -65 - 150 °C

Instructions for MAX392CSE+T

  1. Power Supply:

    • Ensure the supply voltage (VCC) is within the specified range of 4.5V to 5.5V to avoid damage or improper operation.
  2. Input Signal:

    • The input voltage should not exceed VCC + 0.3V and should not be less than -0.3V relative to ground to prevent damage to the device.
  3. Output Configuration:

    • For proper output levels, ensure that the high-level output does not exceed VCC - 0.8V and the low-level output remains below 0.8V.
  4. Thermal Considerations:

    • Keep the power dissipation within the maximum limit of 160mW to avoid overheating.
    • Operate the device within the temperature range of -40°C to 85°C for optimal performance.
  5. Storage:

    • When storing the device, ensure the temperature does not drop below -65°C or rise above 150°C to maintain component integrity.
  6. Handling:

    • Follow standard ESD (Electrostatic Discharge) precautions when handling the device to prevent damage from static electricity.
(For reference only)

View more about MAX392CSE+T on main site