SKIIP28ANB16V1

SKIIP28ANB16V1

Category: Modules

Specifications
SKU
12374229
Details

BUY SKIIP28ANB16V1 https://www.utsource.net/itm/p/12374229.html

Parameter Description Min Typ Max Unit
VDC DC Input Voltage 500 - 800 V
IC Continuous Collector Current - 1600 - A
IC,peak Peak Collector Current (10 μs, 1% duty cycle) - 3200 - A
Tj Junction Temperature -40 - 175 °C
Rth(j-c) Thermal Resistance, Junction to Case - 0.14 - K/W
Rth(c-s) Thermal Resistance, Case to Heat Sink - 0.01 - K/W
fsw Switching Frequency - - 20 kHz
VCE(sat) Collector-Emitter Saturation Voltage at IC = 1600 A, VGE = 15 V - 2.0 - V
Eon Turn-On Energy at IC = 1600 A, VDC = 800 V - 150 - mJ
Eoff Turn-Off Energy at IC = 1600 A, VDC = 800 V - 120 - mJ
td(on) Turn-On Delay Time - 0.15 - μs
tr Rise Time - 0.3 - μs
td(off) Turn-Off Delay Time - 0.15 - μs
tf Fall Time - 0.3 - μs

Instructions for Use:

  1. Mounting:

    • Ensure proper heat sinking to maintain the junction temperature within the specified range.
    • Use thermal paste or thermal interface material between the module and the heat sink to improve thermal conductivity.
  2. Electrical Connections:

    • Connect the DC input voltage within the specified range (500 V to 800 V).
    • Ensure that the continuous collector current does not exceed 1600 A.
    • For peak currents, do not exceed 3200 A for durations of 10 μs with a 1% duty cycle.
  3. Thermal Management:

    • Monitor the junction temperature to ensure it does not exceed 175°C.
    • Use the provided thermal resistance values to calculate the required heat sink size and cooling method.
  4. Switching Operations:

    • Operate within the switching frequency limit of up to 20 kHz.
    • Be aware of the turn-on and turn-off energies to optimize the drive circuit and minimize power losses.
  5. Storage and Handling:

    • Store the module in a dry, cool place away from direct sunlight and corrosive environments.
    • Handle with care to avoid mechanical damage or electrostatic discharge (ESD).
  6. Safety Precautions:

    • Follow all safety guidelines and regulations when handling high-voltage and high-current components.
    • Ensure proper grounding and isolation to prevent electrical hazards.
(For reference only)

View more about SKIIP28ANB16V1 on main site