Details
BUY SKIIP28ANB16V1 https://www.utsource.net/itm/p/12374229.html
Parameter | Description | Min | Typ | Max | Unit |
---|---|---|---|---|---|
VDC | DC Input Voltage | 500 | - | 800 | V |
IC | Continuous Collector Current | - | 1600 | - | A |
IC,peak | Peak Collector Current (10 μs, 1% duty cycle) | - | 3200 | - | A |
Tj | Junction Temperature | -40 | - | 175 | °C |
Rth(j-c) | Thermal Resistance, Junction to Case | - | 0.14 | - | K/W |
Rth(c-s) | Thermal Resistance, Case to Heat Sink | - | 0.01 | - | K/W |
fsw | Switching Frequency | - | - | 20 | kHz |
VCE(sat) | Collector-Emitter Saturation Voltage at IC = 1600 A, VGE = 15 V | - | 2.0 | - | V |
Eon | Turn-On Energy at IC = 1600 A, VDC = 800 V | - | 150 | - | mJ |
Eoff | Turn-Off Energy at IC = 1600 A, VDC = 800 V | - | 120 | - | mJ |
td(on) | Turn-On Delay Time | - | 0.15 | - | μs |
tr | Rise Time | - | 0.3 | - | μs |
td(off) | Turn-Off Delay Time | - | 0.15 | - | μs |
tf | Fall Time | - | 0.3 | - | μs |
Instructions for Use:
Mounting:
- Ensure proper heat sinking to maintain the junction temperature within the specified range.
- Use thermal paste or thermal interface material between the module and the heat sink to improve thermal conductivity.
Electrical Connections:
- Connect the DC input voltage within the specified range (500 V to 800 V).
- Ensure that the continuous collector current does not exceed 1600 A.
- For peak currents, do not exceed 3200 A for durations of 10 μs with a 1% duty cycle.
Thermal Management:
- Monitor the junction temperature to ensure it does not exceed 175°C.
- Use the provided thermal resistance values to calculate the required heat sink size and cooling method.
Switching Operations:
- Operate within the switching frequency limit of up to 20 kHz.
- Be aware of the turn-on and turn-off energies to optimize the drive circuit and minimize power losses.
Storage and Handling:
- Store the module in a dry, cool place away from direct sunlight and corrosive environments.
- Handle with care to avoid mechanical damage or electrostatic discharge (ESD).
Safety Precautions:
- Follow all safety guidelines and regulations when handling high-voltage and high-current components.
- Ensure proper grounding and isolation to prevent electrical hazards.
View more about SKIIP28ANB16V1 on main site