Parameter Description Value Unit
Part Number Component Identifier SEMIX703GB126V1 -
Type Device Type IGBT Module -
Technology Manufacturing Process Trench Gate Field Stop (FGFS) -
Package Housing Type SEMITOP E -
Rated Voltage (Vce) Maximum Collector-Emitter Voltage 1200 V
Rated Current (Ic) Continuous Collector Current 700 A
Peak Collector Current (Icm) Non-Repetitive Peak Collector Current 1400 A
Collector-Emitter Saturation Voltage (Vce(sat)) Collector-Emitter Saturation Voltage at Ic = 700A, Vge = 15V 1.8 V
Turn-On Time (ton) Turn-On Time 0.9 μs
Turn-Off Time (toff) Turn-Off Time 1.2 μs
Thermal Resistance (Rth(j-c)) Junction to Case Thermal Resistance 0.12 K/W
Operating Temperature Range (Tj) Junction Temperature Range -40 to 150 °C
Storage Temperature Range (Tstg) Storage Temperature Range -40 to 150 °C
Humidity Sensitivity Level (HSL) Humidity Sensitivity Level 1 -

Instructions for Use:

  1. Handling and Storage:

    • Store the module in a dry, cool place to avoid moisture absorption.
    • Handle the module with care to prevent mechanical damage or electrostatic discharge (ESD).
  2. Mounting:

    • Ensure the mounting surface is flat and clean to achieve good thermal contact.
    • Apply a thin, even layer of thermal grease between the module and the heat sink.
    • Torque the mounting screws to the recommended value to ensure proper contact and prevent overheating.
  3. Electrical Connections:

    • Use appropriate wire gauges and connectors to handle the rated current.
    • Ensure all connections are secure to prevent arcing or overheating.
    • Apply a suitable gate drive voltage to ensure reliable operation.
  4. Thermal Management:

    • Monitor the junction temperature to ensure it remains within the specified range.
    • Use a suitable heat sink with adequate cooling capacity to dissipate heat effectively.
  5. Testing:

    • Perform initial testing under controlled conditions to verify proper operation.
    • Regularly inspect the module for signs of wear or damage.
  6. Safety Precautions:

    • Always follow safety guidelines when handling high-voltage and high-current components.
    • Use appropriate personal protective equipment (PPE) when necessary.