Parameter | Description | Value | Unit |
---|---|---|---|
Part Number | Component Identifier | SEMIX703GB126V1 | - |
Type | Device Type | IGBT Module | - |
Technology | Manufacturing Process | Trench Gate Field Stop (FGFS) | - |
Package | Housing Type | SEMITOP E | - |
Rated Voltage (Vce) | Maximum Collector-Emitter Voltage | 1200 | V |
Rated Current (Ic) | Continuous Collector Current | 700 | A |
Peak Collector Current (Icm) | Non-Repetitive Peak Collector Current | 1400 | A |
Collector-Emitter Saturation Voltage (Vce(sat)) | Collector-Emitter Saturation Voltage at Ic = 700A, Vge = 15V | 1.8 | V |
Turn-On Time (ton) | Turn-On Time | 0.9 | μs |
Turn-Off Time (toff) | Turn-Off Time | 1.2 | μs |
Thermal Resistance (Rth(j-c)) | Junction to Case Thermal Resistance | 0.12 | K/W |
Operating Temperature Range (Tj) | Junction Temperature Range | -40 to 150 | °C |
Storage Temperature Range (Tstg) | Storage Temperature Range | -40 to 150 | °C |
Humidity Sensitivity Level (HSL) | Humidity Sensitivity Level | 1 | - |
Instructions for Use:
Handling and Storage:
- Store the module in a dry, cool place to avoid moisture absorption.
- Handle the module with care to prevent mechanical damage or electrostatic discharge (ESD).
Mounting:
- Ensure the mounting surface is flat and clean to achieve good thermal contact.
- Apply a thin, even layer of thermal grease between the module and the heat sink.
- Torque the mounting screws to the recommended value to ensure proper contact and prevent overheating.
Electrical Connections:
- Use appropriate wire gauges and connectors to handle the rated current.
- Ensure all connections are secure to prevent arcing or overheating.
- Apply a suitable gate drive voltage to ensure reliable operation.
Thermal Management:
- Monitor the junction temperature to ensure it remains within the specified range.
- Use a suitable heat sink with adequate cooling capacity to dissipate heat effectively.
Testing:
- Perform initial testing under controlled conditions to verify proper operation.
- Regularly inspect the module for signs of wear or damage.
Safety Precautions:
- Always follow safety guidelines when handling high-voltage and high-current components.
- Use appropriate personal protective equipment (PPE) when necessary.
View more about SEMIX703GB126V1 on main site