VN340SP-E

VN340SP-E


Specifications
SKU
12376924
Details

BUY VN340SP-E https://www.utsource.net/itm/p/12376924.html

Parameter Description Value
Part Number Component Identifier VN340SP-E
Type Component Type N-Channel MOSFET
VDS (Max) Drain-Source Voltage 30V
VGS (Max) Gate-Source Voltage ±20V
ID (Max) Continuous Drain Current 34A
RDS(on) On-State Resistance at VGS = 10V 5.5mΩ
PTOT (Max) Total Power Dissipation 110W
TJ (Max) Junction Temperature 175°C
TSTG Storage Temperature Range -55°C to +175°C
Package Housing Type TO-220AB
Mounting Type Installation Method Through-Hole

Instructions for Use:

  1. Handling Precautions:

    • ESD Protection: Handle the VN340SP-E with care to avoid electrostatic discharge (ESD) damage. Use proper ESD protection equipment such as wrist straps and ESD mats.
    • Thermal Management: Ensure adequate heat dissipation by using a heatsink or thermal compound when operating at high currents or power levels.
  2. Circuit Design:

    • Gate Drive: Apply a gate voltage (VGS) of at least 10V to ensure the MOSFET is fully on and minimize RDS(on). Avoid exceeding the maximum gate-source voltage (±20V).
    • Source Connection: Connect the source terminal to the common ground to ensure proper operation and to avoid floating sources.
    • Drain Load: Ensure the drain load does not exceed the maximum drain current (34A) and that the drain-source voltage (VDS) remains within the rated limit (30V).
  3. Thermal Considerations:

    • Heatsinking: For continuous operation at high currents, use a heatsink with sufficient thermal capacity to keep the junction temperature below 175°C.
    • Thermal Compound: Apply a thin layer of thermal compound between the MOSFET and the heatsink to improve thermal conductivity.
  4. Storage and Handling:

    • Temperature Range: Store the VN340SP-E in a dry environment within the storage temperature range (-55°C to +175°C).
    • Humidity Control: Avoid exposure to high humidity to prevent moisture-related issues.
  5. Testing and Verification:

    • Initial Testing: Before integrating the VN340SP-E into a circuit, perform initial tests to verify its functionality and parameters.
    • Operational Testing: Monitor the temperature and performance during operation to ensure it meets the design requirements and remains within safe operating limits.

By following these guidelines, you can ensure reliable and efficient operation of the VN340SP-E in your application.

(For reference only)

View more about VN340SP-E on main site