YGW60N65F1 China original brand new TO-247 LX

YGW60N65F1 China original brand new TO-247 LX

Category: Transistors

Specifications
SKU
12377821
Details

BUY YGW60N65F1 China original brand new TO-247 LX https://www.utsource.net/itm/p/12377821.html

Parameter Value
Part Number YGW60N65F1
Brand China Original
Package Type TO-247
Device Type MOSFET
Channel Type N-Channel
Drain-Source Voltage 650V
Continuous Drain Current 60A (at 25掳C), 30A (at 100掳C)
Rds(on) 25 m惟 (max) at Vgs = 10V
Gate-Source Voltage 卤20V
Power Dissipation 280W (at 25掳C)
Junction Temperature -55掳C to +150掳C
Storage Temperature -55掳C to +150掳C
Total Gate Charge 110 nC (max)
Input Capacitance 2900 pF (typ) at Vds = 400V, Vgs = 0V
Output Capacitance 100 pF (typ) at Vds = 400V, Vgs = 0V
Reverse Transfer Capacitance 50 pF (typ) at Vds = 400V, Vgs = 0V
Thermal Resistance (RthJC) 0.5掳C/W
Thermal Resistance (RthCS) 2.5掳C/W

Instructions for Use

  1. Handling and Storage:

    • Store in a dry, cool place away from direct sunlight.
    • Handle with care to avoid damage to the leads and body.
    • Use proper ESD (Electrostatic Discharge) precautions to prevent damage.
  2. Mounting:

    • Ensure the mounting surface is clean and flat.
    • Apply a thin layer of thermal compound to the back of the TO-247 package for better heat dissipation.
    • Tighten the mounting screws to the recommended torque (typically 1.5 to 2.5 Nm).
  3. Electrical Connections:

    • Connect the drain (D), source (S), and gate (G) terminals as per the circuit diagram.
    • Ensure all connections are secure and free from shorts or loose contacts.
    • Use appropriate wire gauges to handle the current ratings.
  4. Operating Conditions:

    • Do not exceed the maximum ratings for voltage, current, and temperature.
    • Monitor the junction temperature to ensure it stays within safe limits.
    • Use a heatsink if necessary to manage heat dissipation.
  5. Testing:

    • Before applying power, verify all connections and ensure the circuit is correctly configured.
    • Test the device under controlled conditions to ensure proper operation.
    • Use a multimeter to check continuity and resistance values.
  6. Safety Precautions:

    • Always disconnect power before making any changes to the circuit.
    • Use insulated tools to avoid short circuits.
    • Follow all relevant safety guidelines and regulations.