Details
BUY 6MBP20RH060-50 https://www.utsource.net/itm/p/12378197.html
Parameter | Symbol | Min | Typ | Max | Unit | Notes |
---|---|---|---|---|---|---|
Forward Voltage (at IF = 20 A) | VF | - | 1.7 | 2.0 | V | @ Tj = 25°C |
Reverse Recovery Time (at IRM = 20 A, dI/dt = 200 A/μs) | trr | - | 130 | 180 | ns | @ Tj = 25°C |
Peak Reverse Voltage | VRM | - | - | 600 | V | Continuous |
RMS Voltage (at f = 50 Hz) | VRRMS | - | - | 424 | V | - |
Average Rectified Output Current (at Tj = 100°C) | IF(AV) | - | 20 | - | A | - |
Surge Current (Non-repetitive) | IFSM | - | 200 | - | A | @ Tj = 25°C, t = 10 ms |
Junction to Case Thermal Resistance | Rth(j-c) | - | 0.5 | - | K/W | - |
Storage Temperature Range | Tstg | -40 | - | 150 | °C | - |
Operating Junction Temperature Range | Tj(op) | -40 | - | 150 | °C | - |
Instructions for Use:
Mounting:
- Ensure proper heat sinking to maintain the junction temperature within the specified range.
- Use a thermal compound to enhance thermal conductivity between the device and the heatsink.
Wiring:
- Keep leads as short as possible to minimize inductive effects.
- Ensure good mechanical support for the leads to prevent stress on the device.
Surge Handling:
- The device can handle surge currents up to 200 A for 10 ms. Ensure that the application does not exceed this limit to avoid damage.
Reverse Voltage:
- The peak reverse voltage should not exceed 600 V to prevent breakdown.
Temperature Management:
- Monitor the junction temperature to ensure it stays within the operating range (-40°C to 150°C).
Storage:
- Store the device in a dry, cool place within the storage temperature range (-40°C to 150°C).
Handling:
- Handle with care to avoid mechanical damage. Use appropriate ESD protection to prevent electrostatic discharge damage.
Testing:
- When testing, ensure that all parameters are within the specified limits to avoid premature failure.
Derating:
- For prolonged operation at high temperatures, consider derating the average rectified output current to ensure reliability.
Compliance:
- Ensure that the device complies with all relevant safety and regulatory standards for your specific application.
View more about 6MBP20RH060-50 on main site