Details
BUY TLP741G https://www.utsource.net/itm/p/12379498.html
| Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
|---|---|---|---|---|---|---|
| Forward Voltage | VF | IF = 20 mA | 1.1 | 1.3 | 1.5 | V |
| Reverse Voltage | VR | IR = 5 mA | - | - | 5 | V |
| Output Current | IO | VO = 5V | 50 | 100 | 150 | mA |
| Propagation Delay Time | tPLH, tPHL | VI = 5V, VO = 5V, IL = 10 mA | - | 20 | 40 | ns |
| Storage Temperature | TSTG | - | -40 | - | 105 | 掳C |
| Operating Temperature | TA | - | -40 | - | 85 | 掳C |
| Isolation Voltage | VIOMAX | 1 min, 50/60 Hz | - | - | 3750 | Vrms |
Instructions for Use:
Power Supply:
- Ensure that the input and output power supplies are within the specified voltage ranges.
- The forward voltage (VF) should be maintained to ensure proper operation.
Current Limiting:
- Use appropriate current-limiting resistors to ensure that the forward current (IF) does not exceed 20 mA.
- Similarly, limit the reverse current (IR) to avoid damage.
Output Load:
- The output current (IO) should not exceed 150 mA to prevent overheating or damage to the device.
- Ensure that the load resistance is compatible with the output current capability.
Propagation Delay:
- Account for the propagation delay time (tPLH, tPHL) in your timing calculations to ensure reliable signal transmission.
Temperature Considerations:
- Operate the device within the specified temperature ranges (TA and TSTG) to avoid performance degradation or failure.
- Ensure adequate cooling if operating near the upper temperature limits.
Isolation:
- The device provides electrical isolation up to 3750 Vrms for 1 minute at 50/60 Hz. Ensure that the isolation requirements of your application are met.
Handling:
- Handle the device with care to avoid static discharge, which can damage sensitive components.
- Follow standard ESD (Electrostatic Discharge) precautions when handling and installing the device.
Mounting:
- Mount the device on a suitable PCB with proper thermal management to dissipate heat effectively.
- Ensure that the PCB layout minimizes noise and interference.
Testing:
- Before finalizing the design, perform thorough testing under various conditions to ensure reliability and performance.
Compliance:
- Ensure that the device meets all relevant safety and regulatory standards for your application.
View more about TLP741G on main site