BUY MCP6022-I/P https://www.utsource.net/itm/p/12380441.html

Parameter Symbol Conditions Min Typ Max Unit
Supply Voltage VDD - 1.8 - 5.5 V
Supply Current (Each Amp) IDD VDD = 5V, G = 1 - 1.3 1.7 渭A
Input Bias Current IB VDD = 5V, TA = 25掳C -100 0 100 nA
Input Offset Voltage VOS VDD = 5V, TA = 25掳C -10 0 10 渭V
Common-Mode Input Range VCM - VSS - 0.3 - VDD + 0.3 V
Output Voltage Swing VOUT No Load, VDD = 5V 0.1 - 4.9 V
Slew Rate SR VDD = 5V, G = 1 - 0.6 - V/渭s
Gain Bandwidth Product GBP VDD = 5V, G = 1 - 1.2 - MHz
Unity Gain Frequency fUG VDD = 5V, G = 1 - 1.2 - MHz
Phase Margin PM VDD = 5V, G = 1 - 60 -
Operating Temperature TA - -40 - 125 掳C

Instructions for Use:

  1. Power Supply:

    • Ensure the supply voltage (VDD) is within the range of 1.8V to 5.5V.
    • Connect the power supply to the VDD and VSS pins.
  2. Input Connections:

    • Connect the input signals to the non-inverting (+) and inverting (-) inputs of each operational amplifier.
    • Ensure the common-mode input voltage (VCM) stays within the range of VSS - 0.3V to VDD + 0.3V.
  3. Output Connections:

    • The output voltage swing can range from 0.1V to 4.9V when no load is connected.
    • Connect the output to the desired load or next stage of the circuit.
  4. Gain Configuration:

    • Set the gain using external resistors. For unity gain, connect the output directly to the inverting input.
    • For higher gains, use a feedback resistor (RF) and an input resistor (RI) with the gain given by G = 1 + RF/RI.
  5. Temperature Considerations:

    • The device is designed to operate over a temperature range of -40掳C to 125掳C.
    • Ensure the ambient temperature does not exceed these limits to avoid damage or performance degradation.
  6. Stability:

    • The phase margin of 60掳 ensures stable operation under most conditions.
    • If stability issues arise, consider adding compensation capacitors or adjusting the gain configuration.
  7. Handling:

    • Handle the device with care to avoid electrostatic discharge (ESD) damage.
    • Follow standard ESD precautions when handling and soldering the device.
  8. Storage:

    • Store the device in a dry, cool place to prevent moisture damage.
    • Follow recommended storage conditions as specified in the datasheet.