Details

BUY LM324PWRG4 https://www.utsource.net/itm/p/12383099.html

Parameter Symbol Conditions Min Typ Max Unit
Supply Voltage VCC Operating Range 3 - 32 V
Input Offset Voltage VIO VCC = 卤15V -5 2 7 mV
Input Bias Current IB VCC = 卤15V 20 80 500 nA
Input Offset Current IOS VCC = 卤15V -10 5 70 nA
Differential Input Voltage Range VID VCC = 卤15V -30 - 30 V
Output Short-Circuit Protection - Continuous - Yes - -
Output Voltage Swing VOUT No Load, VCC = 15V 0 - 14 V
Quiescent Current IQ Per Amplifier 0.4 0.8 1.0 mA
Slew Rate SR VCC = 卤15V 0.5 - - V/渭s
Common-Mode Rejection Ratio CMRR VCC = 卤15V 70 - - dB
Power Dissipation PD Maximum - - 620 mW
Operating Temperature Range TA Commercial Grade 0 - 70 掳C
Storage Temperature Range TSTG -65 - 150 掳C

Instructions for Use:

  1. Power Supply:

    • The LM324PWRG4 can operate from a single supply (3V to 32V) or dual supplies (卤1.5V to 卤16V).
    • Ensure the power supply is stable and within the specified range to avoid damage.
  2. Input Signals:

    • The input signals should be within the common-mode input voltage range.
    • Avoid exceeding the differential input voltage range to prevent damage.
  3. Output Configuration:

    • The output can swing close to the supply rails but may not reach them exactly.
    • For optimal performance, use a load resistor to ground or a pull-up resistor if driving a high-impedance load.
  4. Biasing and Offset:

    • The input bias current and offset current are relatively low but should be considered when designing circuits with high impedance sources.
    • Use compensation capacitors if necessary to stabilize the circuit.
  5. Thermal Management:

    • Ensure adequate heat dissipation, especially at higher power levels.
    • Do not exceed the maximum power dissipation rating.
  6. Storage and Handling:

    • Store the device in a dry environment to prevent moisture damage.
    • Handle with care to avoid static discharge, which can damage the internal components.
  7. Testing and Troubleshooting:

    • Before testing, ensure all connections are correct and secure.
    • Use a multimeter to check for short circuits and open circuits.
    • If the device does not function as expected, check the power supply, input signals, and output loads.
(For reference only)

View more about LM324PWRG4 on main site