LM324PWRG4
Category: Elec-componentLinear - Amplifiers - Instrumentation, OP Amps, Buffer AmpsIntegrated CircuitAmplifiers - Instrumentation, OP Amps, Buffer Amps
Specifications
SKU
12383099
Details
BUY LM324PWRG4 https://www.utsource.net/itm/p/12383099.html
| Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
|---|---|---|---|---|---|---|
| Supply Voltage | VCC | Operating Range | 3 | - | 32 | V |
| Input Offset Voltage | VIO | VCC = 卤15V | -5 | 2 | 7 | mV |
| Input Bias Current | IB | VCC = 卤15V | 20 | 80 | 500 | nA |
| Input Offset Current | IOS | VCC = 卤15V | -10 | 5 | 70 | nA |
| Differential Input Voltage Range | VID | VCC = 卤15V | -30 | - | 30 | V |
| Output Short-Circuit Protection | - | Continuous | - | Yes | - | - |
| Output Voltage Swing | VOUT | No Load, VCC = 15V | 0 | - | 14 | V |
| Quiescent Current | IQ | Per Amplifier | 0.4 | 0.8 | 1.0 | mA |
| Slew Rate | SR | VCC = 卤15V | 0.5 | - | - | V/渭s |
| Common-Mode Rejection Ratio | CMRR | VCC = 卤15V | 70 | - | - | dB |
| Power Dissipation | PD | Maximum | - | - | 620 | mW |
| Operating Temperature Range | TA | Commercial Grade | 0 | - | 70 | 掳C |
| Storage Temperature Range | TSTG | -65 | - | 150 | 掳C |
Instructions for Use:
Power Supply:
- The LM324PWRG4 can operate from a single supply (3V to 32V) or dual supplies (卤1.5V to 卤16V).
- Ensure the power supply is stable and within the specified range to avoid damage.
Input Signals:
- The input signals should be within the common-mode input voltage range.
- Avoid exceeding the differential input voltage range to prevent damage.
Output Configuration:
- The output can swing close to the supply rails but may not reach them exactly.
- For optimal performance, use a load resistor to ground or a pull-up resistor if driving a high-impedance load.
Biasing and Offset:
- The input bias current and offset current are relatively low but should be considered when designing circuits with high impedance sources.
- Use compensation capacitors if necessary to stabilize the circuit.
Thermal Management:
- Ensure adequate heat dissipation, especially at higher power levels.
- Do not exceed the maximum power dissipation rating.
Storage and Handling:
- Store the device in a dry environment to prevent moisture damage.
- Handle with care to avoid static discharge, which can damage the internal components.
Testing and Troubleshooting:
- Before testing, ensure all connections are correct and secure.
- Use a multimeter to check for short circuits and open circuits.
- If the device does not function as expected, check the power supply, input signals, and output loads.
View more about LM324PWRG4 on main site