Device Type 512K x 8-bit Flash Memory
Manufacturer Atmel (now part of Microchip Technology)
Package Type 40-Pin Plastic Dual Inline Package (PDIP), 44-Pin Thin Small Outline Package (TSOP)
Operating Voltage (Vcc) 2.7V to 6.0V
Programming Voltage (Vpp) Same as Vcc, no separate programming voltage required
Access Time 120ns (for -12TC suffix)
Endurance 10,000 Program/Erase Cycles
Data Retention 20 years at 85°C
Temperature Range Commercial: 0°C to +70°C, Industrial: -40°C to +85°C
Organization 512K x 8 bits
Block Structure Uniform sector organization with 8 sectors of 64K bits each
Features Auto Select Programming Mode, Sector Protection

Instructions for AT29C040A-12TC

  1. Power Supply Connection

    • Connect Vcc to the positive power supply (2.7V to 6.0V).
    • Connect GND to the ground.
  2. Address Lines

    • Connect address lines A0-A18 to select the memory location you wish to access.
  3. Data Lines

    • Connect data lines D0-D7 to the microcontroller or processor data bus.
  4. Control Signals

    • OE (Output Enable): Low active signal to enable reading from the device.
    • WE (Write Enable): Low active signal used in conjunction with CE and OE during write operations.
    • CE (Chip Enable): Low active signal to enable the chip.
  5. Programming Mode

    • To enter programming mode, apply the correct sequence of signals on the control lines as specified in the datasheet.
    • Ensure that the programming voltage (if required) is applied correctly.
  6. Sector Protection

    • The device supports sector protection which can be enabled by writing specific values to designated addresses.
  7. Auto Select Programming Mode

    • The device automatically selects between byte program, block erase, and read modes based on the input sequence.
  8. Erase Operations

    • Perform a sector erase by applying the appropriate command sequence to the control lines and providing the sector address.
  9. Read Operations

    • To read data, ensure CE and OE are low, then provide the address and read the data from the data lines.
  10. Handling Precautions

    • Avoid exposing the device to voltages outside the specified operating range.
    • Use proper ESD precautions when handling the device.

Refer to the detailed datasheet for timing diagrams and exact command sequences for various operations.