Details
BUY REF01CPZ https://www.utsource.net/itm/p/12398994.html
Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
---|---|---|---|---|---|---|
Input Voltage Range | VIN | - | 2.7 | - | 40 | V |
Output Voltage | VOUT | - | - | 2.5 | - | V |
Line Regulation | ΔVOUT/ΔVIN | VIN = 2.7V to 40V | - | 5 | - | ppm/V |
Load Regulation | ΔVOUT/ΔIOUT | IOUT = 100μA to 10mA | - | 5 | - | ppm/mA |
Temperature Coefficient | TCO | -40°C to +85°C | - | 10 | - | ppm/°C |
Initial Accuracy | ΔVOUT | - | - | ±0.025 | - | % |
Output Noise Voltage | VNOISE | 0.1Hz to 10Hz | - | 3 | - | μVrms |
Quiescent Current | IQ | VIN = 5V, IOUT = 0 | - | 60 | - | μA |
Dropout Voltage | VDROPOUT | IOUT = 10mA | - | 2 | - | mV |
Operating Temperature Range | TOPR | - | -40 | - | +85 | °C |
Storage Temperature Range | TSTG | - | -65 | - | +150 | °C |
Instructions for Use:
Power Supply:
- Ensure the input voltage (VIN) is within the range of 2.7V to 40V.
- Use a stable power supply to avoid fluctuations that could affect the output voltage.
Output Voltage:
- The REF01CPZ provides a precise 2.5V output voltage.
- For best accuracy, ensure the load current (IOUT) is between 100μA and 10mA.
Line Regulation:
- The line regulation is specified as 5 ppm/V, meaning the output voltage will change by 5 parts per million for every volt change in the input voltage.
Load Regulation:
- The load regulation is specified as 5 ppm/mA, indicating the output voltage will change by 5 parts per million for every milliamp change in the load current.
Temperature Coefficient:
- The temperature coefficient is 10 ppm/°C, meaning the output voltage will change by 10 parts per million for every degree Celsius change in temperature.
Initial Accuracy:
- The initial accuracy of the output voltage is ±0.025%, ensuring high precision in applications requiring accurate voltage references.
Output Noise:
- The output noise voltage is 3 μVrms over the frequency range of 0.1Hz to 10Hz, making it suitable for low-noise applications.
Quiescent Current:
- The quiescent current is 60 μA at 5V input with no load, which is relatively low and helps in power-efficient designs.
Dropout Voltage:
- The dropout voltage is 2 mV at 10 mA load current, allowing the device to operate even when the input voltage is very close to the output voltage.
Operating and Storage Temperature:
- Operate the device within the temperature range of -40°C to +85°C for optimal performance.
- Store the device in a temperature range of -65°C to +150°C to ensure long-term reliability.
Handling and Installation:
- Handle the device with care to avoid damage from electrostatic discharge (ESD).
- Follow proper soldering techniques to ensure reliable connections and avoid thermal stress on the device.