Details
BUY L9613B https://www.utsource.net/itm/p/12401662.html
| Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
|---|---|---|---|---|---|---|
| Supply Voltage | Vcc | Operating | 4.5 | - | 24 | V |
| Output Current | Iout | Continuous, per channel | - | 0.6 | 1 | A |
| Peak Output Current | Iout(p) | Per channel | - | 1.2 | 1.5 | A |
| Quiescent Current | IQ | No load | 10 | - | 30 | mA |
| Shutdown Current | ISD | Vsd = Vcc, no load | 0.1 | - | 0.5 | μA |
| Thermal Shutdown | TSD | Activation | - | 160 | - | °C |
| Operating Temperature | Topr | Junction | -40 | - | 125 | °C |
Instructions for L9613B:
Power Supply Connection:
- Connect the supply voltage (Vcc) within the range of 4.5V to 24V.
- Ensure that the power supply can handle the peak current requirements of the device.
Output Configuration:
- The L9613B has two open-drain outputs. Each output can handle a continuous current up to 0.6A and peak currents up to 1.5A.
- External pull-up resistors are required for the outputs to function properly.
Quiescent and Shutdown Current:
- In normal operation, the quiescent current should not exceed 30mA.
- When in shutdown mode, ensure the supply voltage is applied to the shutdown pin (Vsd) to reduce the current draw to less than 0.5μA.
Thermal Considerations:
- Monitor the junction temperature to avoid exceeding 160°C, which triggers thermal shutdown.
- Use appropriate heat sinking if operating near the upper limits of the temperature range.
Operating Temperature Range:
- The device is rated to operate between -40°C and 125°C. Ensure environmental conditions do not exceed these limits.
Handling and Storage:
- Follow standard ESD precautions when handling the device.
- Store in a dry environment to prevent damage from moisture.
Application Notes:
- Refer to the datasheet for detailed application circuits and layout recommendations.
- Verify all connections before applying power to avoid potential damage.
View more about L9613B on main site