SKM200GB128D

SKM200GB128D

Category: Modules

Specifications
SKU
12402999
Details

BUY SKM200GB128D https://www.utsource.net/itm/p/12402999.html

Parameter Symbol Min Typical Max Unit Condition
Collector-Emitter Voltage Vceo - - 1200 V
Collector-Base Voltage Vcbo - - 1200 V
Emitter-Base Voltage Vebo - - 7 V
Continuous Collector Current Ic - - 200 A Tc = 25°C
Continuous Collector Current Ic - - 150 A Tc = 100°C
Pulse Collector Current Icm - - 300 A tp = 10 ms, Icav = 200 A
Power Dissipation Ptot - - 1500 W Tc = 25°C
Power Dissipation Ptot - - 1200 W Tc = 100°C
Junction Temperature Tj - - 150 °C
Storage Temperature Range Tstg -40 - 150 °C
Gate Charge Qg - 55 - nC Vge = 15 V, Ic = 100 A
Total Gate-Charge Qgt - 130 - nC Vge = 15 V, Ic = 100 A
Turn-on Delay Time tdon - 0.6 - μs Vge = 15 V, Ic = 100 A
Rise Time tr - 0.5 - μs Vge = 15 V, Ic = 100 A
Turn-off Delay Time tdoff - 0.7 - μs Vge = -15 V, Ic = 100 A
Fall Time tf - 0.4 - μs Vge = -15 V, Ic = 100 A

Instructions for Use:

  1. Mounting and Handling:

    • Ensure proper heat sinking to manage thermal resistance.
    • Handle with care to avoid damage to the leads and body.
  2. Operating Conditions:

    • Do not exceed the maximum ratings listed in the table.
    • Ensure the junction temperature (Tj) does not exceed 150°C.
    • Use appropriate gate drive circuits to ensure reliable switching.
  3. Storage:

    • Store in a dry, cool place within the specified storage temperature range (-40°C to 150°C).
    • Avoid exposure to high humidity and corrosive environments.
  4. Testing:

    • Perform initial testing at room temperature to verify functionality.
    • Gradually increase load and environmental conditions to ensure stability under operational parameters.
  5. Safety:

    • Use protective equipment when handling high-voltage components.
    • Follow all relevant safety guidelines and regulations.
  6. Soldering:

    • Preheat the device to reduce thermal shock.
    • Use a soldering iron with a controlled temperature and apply solder quickly to minimize heat exposure.
  7. Troubleshooting:

    • If the device fails to operate correctly, check for proper connections, correct polarity, and any damage to the leads or body.
    • Refer to the datasheet for more detailed troubleshooting steps and contact the manufacturer for further assistance.
(For reference only)