Details
BUY SB2060FCT https://www.utsource.net/itm/p/12403657.html
| Parameter | Symbol | Min | Typ | Max | Unit | Notes |
|---|---|---|---|---|---|---|
| Forward Voltage | Vf | - | 1.5 | 2.0 | V | @ If = 20A, Ta = 25°C |
| Reverse Voltage | Vr | - | - | 600 | V | |
| Average Rectified Current | Io | - | 20 | - | A | @ Tc = 75°C, 50/60 Hz |
| Peak Surge Current | Ifsm | - | 300 | - | A | @ Tj = 150°C, 10 ms, single pulse |
| Junction Temperature | Tj | - | - | 150 | °C | |
| Storage Temperature | Ts | -40 | - | 150 | °C | |
| Operating Temperature | Ta | -40 | - | 125 | °C | |
| Thermal Resistance (J-C) | RthJC | - | 0.5 | - | °C/W | |
| Thermal Resistance (C-A) | RthCA | - | 20 | - | °C/W |
Instructions for Use:
Mounting:
- Ensure proper heat sinking to maintain junction temperature within safe limits.
- Use recommended mounting torque to avoid damage.
Electrical Connections:
- Connect the diode in the correct polarity to prevent reverse breakdown.
- Use short leads to minimize inductive effects.
Thermal Management:
- Ensure adequate cooling to keep the junction temperature below 150°C.
- Monitor the temperature during operation to avoid overheating.
Surge Handling:
- The diode can handle peak surge currents up to 300A for short durations (10 ms). Ensure that surge conditions do not exceed these limits.
Storage:
- Store the diode in a dry, cool place to prevent moisture damage.
- Avoid exposure to extreme temperatures or corrosive environments.
Handling:
- Handle with care to avoid mechanical damage.
- Use appropriate ESD protection to prevent static damage.
Testing:
- Test the diode under controlled conditions to ensure it meets the specified parameters.
- Refer to the datasheet for detailed test procedures and conditions.
Compliance:
- Ensure that the application complies with relevant safety and regulatory standards.
View more about SB2060FCT on main site