Details
BUY A3959SLBTR https://www.utsource.net/itm/p/12404079.html
Parameter | Symbol | Min | Typ | Max | Unit | Description |
---|---|---|---|---|---|---|
Supply Voltage | VDD | 8.0 | - | 52.0 | V | Operating voltage range |
Logic Supply Voltage | VLOGIC | 2.7 | - | 5.5 | V | Logic supply voltage range |
Maximum Phase Current | ILIM | - | 1.5 | 3.0 | A | Peak current limit |
Thermal Shutdown | TSD | - | - | 160 | °C | Temperature at which thermal shutdown occurs |
Under Voltage Lockout | UVLO | 8.0 | - | - | V | Minimum input voltage for normal operation |
Standby Current | ISB | - | 40 | - | μA | Quiescent current in standby mode |
Operating Temperature | TOPR | -40 | - | 150 | °C | Operating junction temperature range |
Instructions for Use:
Power Supply Connection:
- Connect the VDD pin to a power supply within the range of 8V to 52V.
- Ensure VLOGIC is connected to a supply between 2.7V and 5.5V.
Current Limiting:
- Adjust the ILIM resistor to set the peak phase current limit as required by your application, typically between 1.5A and 3.0A.
Thermal Considerations:
- Monitor the device temperature to ensure it does not exceed 160°C to prevent thermal shutdown.
Under Voltage Lockout:
- Verify that the input voltage remains above 8V to avoid entering under voltage lockout (UVLO).
Standby Mode:
- In standby mode, the device consumes approximately 40μA. Ensure this is accounted for in low-power applications.
Temperature Range:
- Operate the device within a junction temperature range of -40°C to 150°C for reliable performance.
For detailed specifications and additional information, refer to the official datasheet provided by the manufacturer.
(For reference only)View more about A3959SLBTR on main site