Details
BUY SP491EEN https://www.utsource.net/itm/p/12420137.html
| Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
|---|---|---|---|---|---|---|
| Supply Voltage | VDD | - | 2.7 | - | 5.5 | V |
| Operating Temperature | TA | - | -40 | - | 85 | °C |
| Storage Temperature | TSTG | - | -65 | - | 150 | °C |
| Input Voltage (High) | VIH | IIL = -1 μA | 2.0 | - | VDD | V |
| Input Voltage (Low) | VIL | IIL = 1 μA | 0 | - | 0.8 | V |
| Output Voltage (High) | VOH | IOL = -4 mA | 2.4 | - | VDD - 0.4 | V |
| Output Voltage (Low) | VOL | IOL = 16 mA | 0 | - | 0.4 | V |
| Propagation Delay Time | tpLH, tpHL | VDD = 5 V, VOH = 3.5 V, VOL = 0.5 V | - | 12 | - | ns |
| Power Consumption | PD | VDD = 5 V, fo = 1 MHz | - | 1.5 | - | mW |
Instructions for Using SP491EEN
Supply Voltage:
- Ensure the supply voltage (VDD) is within the range of 2.7 V to 5.5 V. Exceeding this range can damage the device.
Operating Temperature:
- The device is designed to operate within a temperature range of -40°C to 85°C. Avoid exposing the device to temperatures outside this range during operation.
Storage Temperature:
- Store the device in an environment where the temperature ranges from -65°C to 150°C to ensure long-term reliability.
Input Voltage Levels:
- For a high input (VIH), the voltage should be at least 2.0 V when IIL is -1 μA.
- For a low input (VIL), the voltage should not exceed 0.8 V when IIL is 1 μA.
Output Voltage Levels:
- For a high output (VOH), the voltage should be at least 2.4 V when IOL is -4 mA.
- For a low output (VOL), the voltage should not exceed 0.4 V when IOL is 16 mA.
Propagation Delay Time:
- The propagation delay time (tpLH, tpHL) should be no more than 12 ns under the specified conditions (VDD = 5 V, VOH = 3.5 V, VOL = 0.5 V).
Power Consumption:
- The power consumption (PD) should be around 1.5 mW under the specified conditions (VDD = 5 V, fo = 1 MHz).
Handling Precautions:
- Handle the device with care to avoid static discharge, which can damage the internal components.
- Ensure all connections are secure and free from shorts or open circuits.
Mounting and Soldering:
- Follow recommended soldering profiles to avoid thermal stress that could damage the device.
- Use appropriate flux and cleaning agents to ensure reliable connections.
Testing:
- Before integrating the device into a circuit, perform initial tests to verify its functionality and parameters.
By adhering to these specifications and instructions, you can ensure optimal performance and longevity of the SP491EEN device.
(For reference only)View more about SP491EEN on main site