Parameter Symbol Min Typ Max Unit Description
Supply Voltage VCC 2.0 - 6.0 V Operating supply voltage range
Input Voltage (High) VIH 3.15 - VCC V Minimum input voltage to be recognized as high
Input Voltage (Low) VIL 0 - 0.85 V Maximum input voltage to be recognized as low
Output Voltage (High) VOH 2.4 - VCC - 0.1 V Minimum output voltage when high
Output Voltage (Low) VOL 0 - 0.1 V Maximum output voltage when low
Input Current IIN - 1 20 渭A Maximum current per input pin
Output Current (Source) IOH - 4 25 mA Maximum current sourced by each output
Output Current (Sink) IOL - 8 25 mA Maximum current sunk by each output
Propagation Delay Time tpd - 15 50 ns Typical propagation delay time from input to output
Power Consumption Ptot - 10 100 mW Total power consumption at VCC = 5V, TA = 25掳C
Operating Temperature TA -40 - 85 掳C Ambient operating temperature range
Storage Temperature TSTG -65 - 150 掳C Temperature range for storage

Instructions for Use:

  1. Power Supply:

    • Ensure the supply voltage (VCC) is within the specified range of 2.0V to 6.0V.
    • Connect the ground (GND) pin to a stable ground reference.
  2. Input Signals:

    • Apply input signals that comply with the VIH and VIL specifications.
    • Avoid exceeding the maximum input current (IIN).
  3. Output Loads:

    • Ensure the load connected to the output pins does not exceed the maximum source (IOH) or sink (IOL) currents.
    • Consider using external pull-up or pull-down resistors if necessary to maintain proper logic levels.
  4. Propagation Delay:

    • Account for the typical propagation delay time (tpd) in your timing calculations to ensure reliable operation.
  5. Temperature Considerations:

    • Operate the device within the specified ambient temperature range (TA) to avoid thermal stress.
    • Store the device within the storage temperature range (TSTG) to prevent damage.
  6. Handling:

    • Handle the device with care to avoid static discharge, which can damage sensitive components.
    • Follow standard ESD (Electrostatic Discharge) precautions during assembly and testing.
  7. Testing:

    • Test the device under typical operating conditions to verify its functionality.
    • Use a multimeter to check for proper voltage levels and current draw.

By following these guidelines, you can ensure reliable and efficient operation of the 74HC273D.

(For reference only)

View more about 74HC273D on main site