Parameter | Symbol | Min | Typical | Max | Unit |
---|---|---|---|---|---|
Supply Voltage | VDD | 2.7 | - | 5.5 | V |
Operating Temperature Range | Toperating | -40 | - | 85 | °C |
Storage Temperature Range | Tstorage | -65 | - | 150 | °C |
Digital Potentiometer Resistance | Rpot | - | 10 | - | kΩ |
Wiper Resistance | Rwiper | - | 100 | - | Ω |
Resistance Tolerance | - | - | ±20 | - | % |
Linearity Error | - | - | ±0.2 | - | % |
End-to-End Resistance | - | - | 10 | - | kΩ |
Power Dissipation | Ptot | - | 150 | - | mW |
Output Current (Sink) | Isink | - | 25 | - | mA |
Output Current (Source) | Isource | - | 25 | - | mA |
Digital Interface | - | SPI, I2C | - | - | - |
Number of Channels | - | - | 1 | - | - |
Instructions for Using AD5241BR100:
Power Supply:
- Ensure the supply voltage (VDD) is within the range of 2.7V to 5.5V.
- Connect the VDD pin to the power supply and GND to ground.
Temperature Considerations:
- The operating temperature range is from -40°C to 85°C.
- Store the device within the storage temperature range of -65°C to 150°C.
Digital Potentiometer Configuration:
- The potentiometer resistance is fixed at 10kΩ with a tolerance of ±20%.
- The wiper resistance is typically 100Ω.
Linearity and Accuracy:
- The linearity error is ±0.2%, ensuring accurate resistance settings.
- The end-to-end resistance is 10kΩ.
Power Dissipation:
- The maximum power dissipation is 150mW. Ensure proper heat dissipation if operating near this limit.
Current Handling:
- The output can sink or source up to 25mA of current.
Digital Interface:
- The device supports both SPI and I2C interfaces for communication.
- Refer to the specific protocol documentation for detailed command structures.
Channel Configuration:
- The AD5241BR100 has one channel of digital potentiometer.
Initialization and Operation:
- Initialize the device by setting the appropriate configuration registers via the digital interface.
- Use the digital interface to adjust the wiper position and control the resistance value.
Safety and Handling:
- Handle the device with care to avoid static damage.
- Follow standard ESD (Electrostatic Discharge) precautions during handling and installation.