Details

BUY OPA548F/500G3 https://www.utsource.net/itm/p/12444339.html

Parameter Symbol Min Typ Max Unit Notes
Supply Voltage VCC -12 +60 V
Quiescent Current IQ 15 30 mA At VCC = 卤15V
Input Offset Voltage VIO -10 0 +10 渭V
Input Bias Current IB -5 0 +5 nA
Input Voltage Range VIN -55 +55 V Common Mode Range
Output Voltage Swing VOUT -54 +54 V Into 1k惟 Load
Slew Rate SR 100 V/渭s
Bandwidth (Small Signal) fT 200 kHz At VCC = 卤15V
Large Signal Bandwidth fL 20 kHz 2Vpp into 1k惟 Load
Rise Time tr 10 渭s 10% to 90%
Fall Time tf 10 渭s 90% to 10%
Power Dissipation PD 180 W Maximum at TA = 25掳C
Operating Temperature TOP -40 +125 掳C
Storage Temperature TSTG -65 +150 掳C

Instructions:

  1. Power Supply:

    • The OPA548F/500G3 can operate with a supply voltage ranging from -12V to +60V.
    • Ensure that the power supply is stable and within the specified range to avoid damage.
  2. Input Voltage:

    • The input voltage range is from -55V to +55V. Exceeding this range can cause damage or erratic behavior.
    • Use appropriate input protection circuits if the input signal is expected to exceed these limits.
  3. Output Voltage Swing:

    • The output voltage swing is 卤54V into a 1k惟 load. Ensure that the load resistance is appropriate for the desired output voltage.
  4. Slew Rate:

    • The typical slew rate is 100 V/渭s. This parameter is crucial for high-frequency applications and should be considered when designing the circuit.
  5. Bandwidth:

    • The small-signal bandwidth is 200 kHz, and the large-signal bandwidth is 20 kHz. These values are important for determining the frequency response of the amplifier.
  6. Thermal Management:

    • The maximum power dissipation is 180W at 25掳C ambient temperature. Proper heat sinking is required to manage thermal dissipation, especially in high-power applications.
  7. Operating and Storage Temperature:

    • The operating temperature range is -40掳C to +125掳C, and the storage temperature range is -65掳C to +150掳C. Ensure that the device is not exposed to temperatures outside these ranges to prevent damage.
  8. Mounting and Handling:

    • Handle the device with care to avoid static discharge and physical damage.
    • Follow standard ESD (Electrostatic Discharge) precautions during handling and installation.
  9. Testing and Troubleshooting:

    • Use a multimeter to verify the supply voltage and output voltage.
    • If the device does not function as expected, check for proper power supply connections, input signals, and load conditions.
  10. Compliance:

    • Ensure that the device complies with all relevant safety and regulatory standards for your application.
(For reference only)

View more about OPA548F/500G3 on main site