Details
BUY TLP181 https://www.utsource.net/itm/p/12444358.html
Parameter | Symbol | Min | Typ | Max | Unit | Conditions |
---|---|---|---|---|---|---|
Forward Voltage | VF | - | 1.2 | 1.6 | V | IF = 20 mA, TA = 25掳C |
Peak Forward Current | IF(P) | - | - | 30 | mA | tP = 10 ms, TA = 25掳C |
Continuous Forward Current | IF | - | - | 20 | mA | TA = 25掳C |
Reverse Voltage | VRRM | - | - | 5 | V | TA = 25掳C |
Output Collector-Emitter Saturation Voltage | VCE(SAT) | - | 0.4 | 0.7 | V | IF = 20 mA, IO = 5 mA, TA = 25掳C |
Output Collector Current | IC | - | - | 5 | mA | TA = 25掳C |
Output Turn-On Time | ton | - | 1 | 3 | 渭s | IF = 20 mA, RL = 100 惟, VCC = 5 V, TA = 25掳C |
Output Turn-Off Time | toff | - | 1 | 3 | 渭s | IF = 20 mA, RL = 100 惟, VCC = 5 V, TA = 25掳C |
Isolation Voltage | VIORM | - | - | 500 | V | 1 minute, 50/60 Hz |
Operating Temperature Range | TA | -40 | - | 110 | 掳C | - |
Instructions for Use:
Forward Current (IF):
- Ensure that the forward current does not exceed 20 mA continuously to avoid damaging the device.
- For short durations (tP = 10 ms), the peak forward current can be up to 30 mA.
Reverse Voltage (VRRM):
- The reverse voltage should not exceed 5 V to prevent breakdown.
Output Collector-Emitter Saturation Voltage (VCE(SAT)):
- When the output is on, the collector-emitter voltage should be between 0.4 V and 0.7 V under typical operating conditions.
Output Collector Current (IC):
- The maximum continuous collector current should not exceed 5 mA.
Turn-On and Turn-Off Times:
- The typical turn-on time is 1 渭s and the turn-off time is also 1 渭s. These times can vary between 1 渭s and 3 渭s depending on the conditions.
Isolation Voltage (VIORM):
- The device provides isolation up to 500 V for 1 minute at 50/60 Hz.
Operating Temperature Range (TA):
- The device can operate in temperatures ranging from -40掳C to 110掳C.
Handling Precautions:
- Handle the device with care to avoid static damage.
- Ensure proper heat dissipation if the device is used in high-temperature environments or with high current loads.
Mounting:
- Mount the device in a way that minimizes mechanical stress and ensures good thermal contact with the PCB or heatsink.
Storage:
- Store the device in a dry, cool place away from direct sunlight and sources of heat.
View more about TLP181 on main site