TLP250

TLP250


Specifications
SKU
12444375
Details

BUY TLP250 https://www.utsource.net/itm/p/12444375.html

Parameter Symbol Conditions Min Typ Max Unit
Supply Voltage VCC Continuous 4.5 - 20 V
Output Current IO Continuous - 150 - mA
Isolation Voltage VIORM 1 minute, 50/60 Hz - - 3750 Vrms
Propagation Delay Time tPLH, tPHL VCC = 5V, IO = 10mA 0.2 - 1.5 渭s
Storage Temperature Tstg - -40 - 105 掳C
Operating Temperature Topr - -40 - 85 掳C
Input Current IF VCC = 5V, VOUT = 5V 5 15 20 mA
Output Low Voltage VON IO = 10mA - 0.3 0.5 V
Output High Voltage VOFF IO = -0.1mA 4.0 - 4.5 V

Instructions for Using TLP250:

  1. Power Supply:

    • Ensure the supply voltage (VCC) is within the range of 4.5V to 20V.
    • The device can operate with a continuous output current (IO) up to 150mA.
  2. Isolation:

    • The TLP250 provides an isolation voltage (VIORM) of up to 3750Vrms for 1 minute at 50/60 Hz.
  3. Timing:

    • The propagation delay time (tPLH, tPHL) should be considered when designing circuits, as it ranges from 0.2渭s to 1.5渭s under typical conditions.
  4. Temperature:

    • Store the device in temperatures ranging from -40掳C to 105掳C.
    • Operate the device within the temperature range of -40掳C to 85掳C.
  5. Input and Output:

    • The input current (IF) should be between 5mA and 20mA for proper operation.
    • The output low voltage (VON) should not exceed 0.5V when the output current (IO) is 10mA.
    • The output high voltage (VOFF) should be between 4.0V and 4.5V when the output current (IO) is -0.1mA.
  6. Handling and Storage:

    • Handle the device with care to avoid damage.
    • Store in a dry, cool place away from direct sunlight and sources of heat.
  7. Mounting:

    • Follow the recommended PCB layout guidelines to ensure optimal performance and reliability.
    • Use appropriate soldering techniques and avoid excessive heat during soldering.
  8. Testing:

    • Before integrating the TLP250 into your circuit, perform initial testing to verify its functionality and parameters.
  9. Safety:

    • Always follow safety guidelines when working with high voltages and isolation requirements.

By adhering to these parameters and instructions, you can ensure reliable and efficient operation of the TLP250 optocoupler in your application.

(For reference only)

View more about TLP250 on main site