Details
BUY TLP2366 https://www.utsource.net/itm/p/12444970.html
Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
---|---|---|---|---|---|---|
Input Current | IF | Continuous | - | 10 | 30 | mA |
Input Voltage | VI | 1.5 | 3.3 | 5.5 | V | |
Output Current | IO | Continuous | - | 1.5 | 3.0 | A |
Peak Output Current | IOP | Pulse Width ≤ 1 ms | - | - | 5.0 | A |
Isolation Voltage | VIORM | 1 min, 50/60 Hz | - | - | 5000 | Vrms |
Propagation Delay Time | tpHL | VI = 5V, IO = 1A | - | 1.2 | 1.8 | μs |
tpLH | VI = 5V, IO = 1A | - | 1.2 | 1.8 | μs | |
Storage Temperature | Tstg | -40 | - | 125 | °C | |
Operating Temperature | Topr | -40 | - | 110 | °C |
Instructions for Use:
Power Supply:
- Ensure the input voltage (VI) is within the specified range (1.5V to 5.5V).
- The input current (IF) should be between 10mA and 30mA for reliable operation.
Output Handling:
- The continuous output current (IO) should not exceed 3A.
- For short pulses (≤ 1 ms), the peak output current (IOP) can go up to 5A.
Isolation:
- The device provides an isolation voltage (VIORM) of 5000Vrms for 1 minute at 50/60 Hz.
Timing:
- The propagation delay time (tpHL and tpLH) is typically 1.2 to 1.8 microseconds when the input voltage is 5V and the output current is 1A.
Temperature:
- Store the device in temperatures ranging from -40°C to 125°C.
- Operate the device within the temperature range of -40°C to 110°C to ensure optimal performance.
Mounting and Handling:
- Handle with care to avoid mechanical stress on the leads and body.
- Follow standard surface mount technology (SMT) procedures for mounting on PCBs.
Testing:
- Before final assembly, test the device under the specified conditions to ensure it meets the required performance parameters.
View more about TLP2366 on main site