Parameter | Symbol | Min | Typ | Max | Unit | Description |
---|---|---|---|---|---|---|
Input Voltage | VIN | 4.5 | - | 40 | V | Operating input voltage range |
Output Voltage | VOUT | - | 5 | - | V | Fixed output voltage |
Output Current | IOUT | - | 1.5 | - | A | Maximum continuous output current |
Quiescent Current | IQ | - | 5 | - | mA | Typical quiescent current |
Dropout Voltage | VDROPOUT | - | 1.2 | - | V | Typical dropout voltage at IOUT = 1.5A |
Power Dissipation | PD | - | - | 18 | W | Maximum power dissipation (TA = 25°C) |
Junction Temperature | TJ | - | - | 150 | °C | Maximum junction temperature |
Storage Temperature | TSTG | -40 | - | 125 | °C | Operating storage temperature range |
Thermal Resistance | RθJA | - | 35 | - | °C/W | Junction-to-ambient thermal resistance |
Instructions for Use:
Input Connection:
- Connect the input voltage (VIN) to the input pin of the KA7500B. Ensure the input voltage is within the specified range (4.5V to 40V).
Output Connection:
- Connect the load to the output pin (VOUT) of the KA7500B. The output voltage is fixed at 5V.
Ground Connection:
- Ensure a common ground connection between the input, output, and load circuits.
Heat Management:
- The KA7500B can dissipate up to 18W of power. For high-power applications, use a heatsink to manage the junction temperature and prevent overheating.
Capacitors:
- Place a 10μF electrolytic capacitor close to the input pin to stabilize the input voltage.
- Place a 10μF electrolytic capacitor close to the output pin to stabilize the output voltage and improve transient response.
Current Limiting:
- The KA7500B has built-in current limiting to protect against overcurrent conditions. The maximum continuous output current is 1.5A.
Thermal Protection:
- The device includes thermal shutdown protection to prevent damage from excessive junction temperatures. Ensure proper ventilation and cooling.
Storage and Handling:
- Store the KA7500B in a dry environment within the specified storage temperature range (-40°C to 125°C).
- Handle with care to avoid damage to the pins and the device itself.
Testing:
- Before connecting the load, test the output voltage with a multimeter to ensure it is stable and within the expected range.
Safety Precautions:
- Always follow safety guidelines when working with electrical components to avoid injury or damage to equipment.