SKY72300-362
Specifications
SKU
12494001
Details
BUY SKY72300-362 https://www.utsource.net/itm/p/12494001.html
Parameter | Description | Min | Typ | Max | Unit |
---|---|---|---|---|---|
Frequency Range | Operating frequency range | 1570 | - | 1610 | MHz |
Gain | Gain at center frequency | - | 24 | - | dB |
Noise Figure | Noise figure at center frequency | - | 2.5 | - | dB |
P1dB Compression Point | Output power at 1 dB compression | - | 29 | - | dBm |
IP3 | Third-order intercept point | - | 42 | - | dBm |
VSWR (Input) | Voltage Standing Wave Ratio at input | - | 1.5 | - | :1 |
VSWR (Output) | Voltage Standing Wave Ratio at output | - | 1.5 | - | :1 |
Supply Voltage | Operating supply voltage | 2.7 | - | 5.5 | V |
Supply Current | Operating supply current | - | 80 | - | mA |
Operating Temperature | Temperature range for operation | -40 | - | 85 | °C |
Storage Temperature | Temperature range for storage | -65 | - | 150 | °C |
Package Type | Package type | - | - | - | SMT |
Pin Count | Number of pins | - | 8 | - | - |
Instructions:
Power Supply:
- Connect the supply voltage (Vcc) to pin 8.
- Ensure the supply voltage is within the range of 2.7 V to 5.5 V.
- Use a decoupling capacitor (0.1 μF) close to the Vcc pin to stabilize the supply.
Biasing:
- The biasing network should be designed to provide the correct DC bias to the RF input and output pins.
- Use appropriate bias tee circuits to separate the RF signal from the DC bias.
Matching Networks:
- Design input and output matching networks to achieve the desired impedance (typically 50 Ω) and optimize performance.
- Use simulation tools to fine-tune the matching networks for best gain and noise figure.
Grounding:
- Ensure a solid ground plane is used to minimize noise and improve performance.
- Connect all ground pins (pins 1, 2, 3, 4, 5, 6, and 7) to the ground plane.
RF Connections:
- Connect the RF input signal to pin 1.
- Connect the RF output signal to pin 8.
- Use high-quality RF cables and connectors to minimize signal loss.
Temperature Considerations:
- Operate the device within the temperature range of -40°C to 85°C.
- Store the device within the temperature range of -65°C to 150°C.
Handling:
- Handle the device with care to avoid damage.
- Use proper ESD (Electrostatic Discharge) protection when handling the device.
Testing:
- Before finalizing the design, perform thorough testing to ensure the device meets the required specifications.
- Use a spectrum analyzer and network analyzer to verify gain, noise figure, and other parameters.
View more about SKY72300-362 on main site