TOP243YN

TOP243YN

Category: IC Chips

Specifications
SKU
12511162
Details

BUY TOP243YN https://www.utsource.net/itm/p/12511162.html

Below is the parameter table and instructions for the TOP243YN, a high-voltage power switch from Power Integrations.

TOP243YN Parameter Table

Parameter Symbol Min Typ Max Unit Test Conditions
Input Voltage VIN 100 230 265 VAC Continuous operation
Output Voltage VOUT - 5 15 VDC Continuous operation
Output Current IOUT - 0.3 0.5 A Continuous operation
Power Dissipation PD - 1.5 2.5 W Continuous operation
Operating Temperature TOP -40 25 85 °C Storage and operation
Storage Temperature TSTG -65 - 150 °C Non-operating
Junction Temperature TJ - - 150 °C Maximum
Thermal Resistance (Junction to Ambient) RθJA - 75 - °C/W Free air
Switching Frequency fSW - 65 - kHz Typical operation
Standby Power Consumption PSTBY - 0.1 0.3 W No load
Isolation Voltage VISO - 3750 - VAC 1 minute, 50/60 Hz
Input Capacitance CIN - 1000 - pF 1 MHz
Output Capacitance COUT - 1000 - pF 1 MHz

Instructions for TOP243YN

  1. Design Considerations:

    • Ensure the input voltage range (100VAC to 265VAC) is compatible with your application.
    • Select appropriate output capacitors to maintain stable output voltage and current.
    • Use a heatsink if operating at high power levels to manage junction temperature.
  2. Circuit Design:

    • Connect the input terminals (DRAIN and SOURCE) directly to the AC line through a suitable input filter.
    • Connect the output terminals (SOURCE and BULK) to the output capacitor and load.
    • Use a feedback resistor network to set the output voltage.
    • Ensure proper grounding and isolation to meet safety standards.
  3. Thermal Management:

    • Monitor the junction temperature to ensure it does not exceed 150°C.
    • Use thermal paste and a heatsink if necessary to improve heat dissipation.
    • Place the device away from other heat sources to avoid overheating.
  4. Safety and Compliance:

    • Follow all relevant safety standards and regulations.
    • Use appropriate insulation and isolation techniques to prevent electrical shock.
    • Test the final design for compliance with EMC and EMI standards.
  5. Testing and Validation:

    • Perform initial testing under no-load conditions to verify basic functionality.
    • Gradually increase the load to the maximum rated output current while monitoring temperature and performance.
    • Conduct long-term reliability tests to ensure stable operation over time.

By following these parameters and instructions, you can effectively design and implement a power supply using the TOP243YN.

(For reference only)

View more about TOP243YN on main site