82C55AC-2

82C55AC-2


Specifications
SKU
12529441
Details

BUY 82C55AC-2 https://www.utsource.net/itm/p/12529441.html

Parameter Symbol Conditions Min Typ Max Unit
Supply Voltage Vcc Operating 4.75 5 5.25 V
Output High Level Voltage VOH IOH = -4mA 2.4 5 V
Output Low Level Voltage VOL IOL = 16mA 0 0.5 V
Input High Level Voltage VIH 2 5.5 V
Input Low Level Voltage VIL 0 0.8 V
Output High Level Current IOH VOH = 2.4V -4 -10 mA
Output Low Level Current IOL VOL = 0.5V 4 8 16 mA
Input Leakage Current IIH VIH = 5V -1 1 μA
Input Leakage Current IIL VIL = 0V -1 1 μA
Power Dissipation PD 320 mW
Operating Temperature Range TA 0 70 °C
Storage Temperature Range Tstg -65 150 °C

Instructions for Using 82C55AC-2

  1. Power Supply:

    • Ensure that the supply voltage (Vcc) is within the range of 4.75V to 5.25V.
    • Connect the ground (GND) pin to a stable ground reference.
  2. Signal Levels:

    • For output pins, ensure that the high-level voltage (VOH) is at least 2.4V when sourcing up to 4mA.
    • For output pins, ensure that the low-level voltage (VOL) is no more than 0.5V when sinking up to 16mA.
    • For input pins, ensure that the high-level voltage (VIH) is at least 2V.
    • For input pins, ensure that the low-level voltage (VIL) is no more than 0.8V.
  3. Current Ratings:

    • The maximum output high-level current (IOH) is -10mA.
    • The typical output low-level current (IOL) is 8mA, with a maximum of 16mA.
    • The input leakage current (IIH and IIL) should be within ±1μA.
  4. Temperature:

    • Operate the device within the temperature range of 0°C to 70°C.
    • Store the device within the temperature range of -65°C to 150°C.
  5. Configuration:

    • Use the control register to configure the mode of operation (Mode 0, Mode 1, or Mode 2) for each port (Port A, Port B, and Port C).
    • Set the direction of each port (input or output) using the control register.
  6. Programming:

    • Write to the control register to set the desired configuration.
    • Read from or write to the data registers of Port A, Port B, and Port C as needed.
  7. Power Dissipation:

    • Ensure that the total power dissipation does not exceed 320mW to avoid overheating.
  8. Handling:

    • Handle the device with care to avoid electrostatic discharge (ESD) damage.
    • Use appropriate ESD protection measures during handling and installation.
  9. Testing:

    • Verify the functionality of the 82C55AC-2 by testing the input and output signals under various conditions to ensure they meet the specified parameters.
(For reference only)

View more about 82C55AC-2 on main site