Details
BUY FDPF51N25 https://www.utsource.net/itm/p/12532382.html
| Parameter | Symbol | Min | Typical | Max | Unit | Conditions |
|---|---|---|---|---|---|---|
| Drain-Source Voltage | VDS | - | 250 | - | V | |
| Gate-Source Voltage | VGS | -15 | - | 20 | V | |
| Continuous Drain Current | ID | - | 44 | - | A | TC = 25°C |
| Power Dissipation | PTOT | - | 180 | - | W | TC = 25°C, Rth(j-c) = 0.63 K/W |
| Junction Temperature | TJ | - | - | 175 | °C | |
| Storage Temperature | TSTG | -55 | - | 150 | °C | |
| Total Gate Charge | QG | - | 40 | - | nC | VGS = 15V, VDS = 250V, ID = 44A |
| Input Capacitance | Ciss | - | 1900 | - | pF | VDS = 250V, f = 1 MHz |
| Output Capacitance | Coss | - | 180 | - | pF | VDS = 250V, f = 1 MHz |
| Reverse Transfer Capacitance | Crss | - | 200 | - | pF | VDS = 250V, f = 1 MHz |
| On-State Resistance | RDS(on) | - | 0.055 | - | Ω | VGS = 10V, ID = 44A, TJ = 25°C |
| Turn-On Delay Time | td(on) | - | 55 | - | ns | VDS = 250V, ID = 44A, VGS = 15V, Rg = 1Ω |
| Rise Time | tr | - | 40 | - | ns | VDS = 250V, ID = 44A, VGS = 15V, Rg = 1Ω |
| Turn-Off Delay Time | td(off) | - | 65 | - | ns | VDS = 250V, ID = 44A, VGS = 15V, Rg = 1Ω |
| Fall Time | tf | - | 35 | - | ns | VDS = 250V, ID = 44A, VGS = 15V, Rg = 1Ω |
Instructions for Use:
Handling and Storage:
- Store in a dry, cool place to prevent moisture damage.
- Handle with care to avoid mechanical stress on the leads and body.
Mounting:
- Ensure proper heat sinking to manage thermal dissipation.
- Use recommended torque values for screw terminals to avoid damage.
Electrical Connections:
- Connect the gate and source terminals carefully to avoid short circuits.
- Use appropriate gate drive circuits to ensure reliable operation.
Operating Conditions:
- Do not exceed the maximum ratings listed in the table.
- Monitor junction temperature to ensure it remains within safe limits.
Testing:
- Perform initial testing under controlled conditions to verify performance.
- Use recommended test circuits and procedures to avoid damaging the device.
Safety:
- Follow all safety guidelines when handling high-voltage and high-current circuits.
- Use protective equipment such as gloves and safety glasses.
Environmental Considerations:
- Dispose of the device according to local environmental regulations.
- Ensure compliance with RoHS and other relevant standards.
View more about FDPF51N25 on main site