PQ30RV11

PQ30RV11


Specifications
SKU
12532579
Details

BUY PQ30RV11 https://www.utsource.net/itm/p/12532579.html

Parameter Symbol Min Typ Max Unit Notes
Input Voltage V_IN 2.7 - 5.5 V
Output Voltage V_OUT - 3.3 - V Fixed
Output Current I_OUT - 1 1.1 A
Quiescent Current I_Q - 10 20 μA
Dropout Voltage V_DO - 200 300 mV
Operating Temperature T_OP -40 - 85 °C
Storage Temperature T_STG -65 - 150 °C
Load Regulation - - 1 3 %
Line Regulation - - 0.1 0.5 %/V
Ripple Rejection - - 60 70 dB @ 1kHz
Transient Response Time t_TR - 20 50 μs
Thermal Resistance (θJA) - - 50 - °C/W

Instructions for Use:

  1. Input Connection:

    • Connect the input voltage (V_IN) to the Vin pin. Ensure the input voltage is within the specified range (2.7V to 5.5V).
  2. Output Connection:

    • Connect the output load to the Vout pin. The maximum output current should not exceed 1.1A.
  3. Ground Connection:

    • Ensure a solid ground connection between the input, output, and any other circuit components.
  4. Capacitors:

    • Place a 1μF ceramic capacitor close to the input pin (Vin) and a 1μF ceramic capacitor close to the output pin (Vout) to ensure stability and reduce noise.
  5. Thermal Management:

    • The device has a thermal resistance of 50°C/W. Ensure adequate heat dissipation if operating at high output currents or in high ambient temperatures.
  6. Operating Temperature:

    • The device is designed to operate within a temperature range of -40°C to 85°C. Avoid exceeding these limits to prevent damage.
  7. Storage Temperature:

    • Store the device in a temperature range of -65°C to 150°C to maintain its integrity.
  8. Load Regulation:

    • The load regulation is typically 1% and can vary up to 3%. Ensure the load does not cause significant changes in the output voltage.
  9. Line Regulation:

    • The line regulation is typically 0.1% per volt and can vary up to 0.5%. Ensure the input voltage is stable to maintain consistent output.
  10. Ripple Rejection:

    • The device provides good ripple rejection, typically 60dB at 1kHz. Use additional filtering if necessary for sensitive applications.
  11. Transient Response:

    • The transient response time is typically 20μs and can vary up to 50μs. Ensure the system can handle this response time for dynamic loads.
  12. Handling:

    • Handle the device with care to avoid static discharge and physical damage. Use appropriate ESD protection when handling.

By following these instructions, you can ensure optimal performance and reliability of the PQ30RV11 regulator.

(For reference only)

View more about PQ30RV11 on main site