Details
BUY DS1302ZN+T&R https://www.utsource.net/itm/p/12532628.html
Parameter | Description | Value/Range |
---|---|---|
Operating Voltage | Supply voltage range for Vcc | 2.5V to 5.5V |
I/O Voltage | Input/output voltage | Vcc - 0.1V to Vcc + 0.3V |
Reset Pin Voltage | Voltage level on RST pin for operation | Vcc - 0.1V to Vcc + 0.3V |
Clock Out Frequency | Frequency of the square wave output | 1Hz, 4kHz, 8kHz, 32kHz |
Write Current | Maximum current during write operations | 100μA |
Standby Current | Current consumption in standby mode | 100nA (typical) |
Operating Temperature | Temperature range for reliable operation | -40°C to +85°C |
Package Type | Type of packaging | SO-8 |
Instructions for DS1302ZN+T&R
Power Supply Connection:
- Connect Vcc to the power supply within the operating voltage range (2.5V to 5.5V).
- Ground all GND pins.
Reset Pin Configuration:
- Apply a logic high to the RST pin to enable communication with the DS1302.
- Ensure that the RST pin is held low when not in use to prevent accidental data changes.
Data Communication:
- Use the SCLK and I/O pins for serial data communication.
- Data is transferred one bit at a time, synchronized by the falling edge of the SCLK signal.
Setting Time and Date:
- Send commands via the I/O pin to set the real-time clock registers.
- Time and date should be sent in BCD format.
Reading Time and Date:
- Command the DS1302 to read the current time and date from its registers.
- Data received will be in BCD format.
Clock Output Control:
- Enable or disable the clock output (CLK OUT) using specific control bits.
- Choose the desired frequency (1Hz, 4kHz, 8kHz, 32kHz) as needed.
Battery Backup:
- For continuous timekeeping during main power loss, connect a backup battery to Vbat.
- Ensure the backup battery voltage is within the operational range.
Handling and Storage:
- Store in a dry environment within the specified temperature range.
- Handle with care to avoid damage to the pins and internal components.
View more about DS1302ZN+T&R on main site