TC962CPA
Category: Elec-component74 series Digital Integrated Circuits74 series Digital Integrated CircuitsIntegrated Circuit
Specifications
SKU
12532714
Details
BUY TC962CPA https://www.utsource.net/itm/p/12532714.html
| Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
|---|---|---|---|---|---|---|
| Output Voltage | Vout | No Load | - | 5.0 | - | V |
| Line Regulation | ΔVout/ΔVin | 4.75V ≤ Vin ≤ 18V | - | 0.05 | - | % |
| Load Regulation | ΔVout/ΔIout | 0mA ≤ Iout ≤ 1000mA | - | 1.0 | - | % |
| Dropout Voltage | Vdo | Iout = 1000mA | - | 2.0 | - | V |
| Quiescent Current | IQ | Vin = 5.5V, No Load | - | 5.0 | - | mA |
| Shutdown Current | ISD | Vin = 5.5V, Shutdown | - | 0.5 | - | μA |
| Output Ripple Rejection | ORR | 10Hz to 100kHz | 60 | 70 | 80 | dB |
| Thermal Shutdown Temperature | TSD | - | 160 | - | °C | |
| Operating Junction Temperature Range | TJ | - | -40 | 125 | °C |
Instructions for Use:
Input Voltage (Vin):
- The input voltage should be within the range of 4.75V to 18V.
- Ensure the input voltage is stable and does not exceed the maximum rating to avoid damage.
Output Voltage (Vout):
- The output voltage is regulated to 5.0V under no load conditions.
- Use appropriate capacitors on the input and output to stabilize the voltage and reduce ripple.
Load Regulation:
- The load regulation is typically 1.0% over the load range from 0mA to 1000mA.
- Ensure the load does not exceed 1000mA to maintain regulation.
Dropout Voltage:
- The dropout voltage is typically 2.0V at a load current of 1000mA.
- Keep the input voltage at least 2.0V higher than the output voltage to ensure proper operation.
Quiescent Current:
- The quiescent current is typically 5.0mA when no load is present.
- This current is drawn by the regulator itself and should be considered in power budgeting.
Shutdown Current:
- The shutdown current is typically 0.5μA when the device is in shutdown mode.
- Use the shutdown pin to turn off the regulator when not in use to save power.
Output Ripple Rejection:
- The output ripple rejection is typically 70dB over the frequency range from 10Hz to 100kHz.
- Use bypass capacitors to further reduce ripple if necessary.
Thermal Shutdown:
- The device will shut down if the junction temperature exceeds 160°C to prevent damage.
- Ensure adequate heat sinking or cooling to keep the device within the operating temperature range.
Operating Temperature:
- The operating junction temperature range is from -40°C to 125°C.
- Ensure the device is used within this range to avoid thermal issues.
Capacitor Selection:
- Use ceramic capacitors with low ESR for input and output filtering.
- Typical values are 10μF for input and 10μF for output, but these can be adjusted based on specific application requirements.
View more about TC962CPA on main site