Details

BUY TC962CPA https://www.utsource.net/itm/p/12532714.html

Parameter Symbol Conditions Min Typ Max Unit
Output Voltage Vout No Load - 5.0 - V
Line Regulation ΔVout/ΔVin 4.75V ≤ Vin ≤ 18V - 0.05 - %
Load Regulation ΔVout/ΔIout 0mA ≤ Iout ≤ 1000mA - 1.0 - %
Dropout Voltage Vdo Iout = 1000mA - 2.0 - V
Quiescent Current IQ Vin = 5.5V, No Load - 5.0 - mA
Shutdown Current ISD Vin = 5.5V, Shutdown - 0.5 - μA
Output Ripple Rejection ORR 10Hz to 100kHz 60 70 80 dB
Thermal Shutdown Temperature TSD - 160 - °C
Operating Junction Temperature Range TJ - -40 125 °C

Instructions for Use:

  1. Input Voltage (Vin):

    • The input voltage should be within the range of 4.75V to 18V.
    • Ensure the input voltage is stable and does not exceed the maximum rating to avoid damage.
  2. Output Voltage (Vout):

    • The output voltage is regulated to 5.0V under no load conditions.
    • Use appropriate capacitors on the input and output to stabilize the voltage and reduce ripple.
  3. Load Regulation:

    • The load regulation is typically 1.0% over the load range from 0mA to 1000mA.
    • Ensure the load does not exceed 1000mA to maintain regulation.
  4. Dropout Voltage:

    • The dropout voltage is typically 2.0V at a load current of 1000mA.
    • Keep the input voltage at least 2.0V higher than the output voltage to ensure proper operation.
  5. Quiescent Current:

    • The quiescent current is typically 5.0mA when no load is present.
    • This current is drawn by the regulator itself and should be considered in power budgeting.
  6. Shutdown Current:

    • The shutdown current is typically 0.5μA when the device is in shutdown mode.
    • Use the shutdown pin to turn off the regulator when not in use to save power.
  7. Output Ripple Rejection:

    • The output ripple rejection is typically 70dB over the frequency range from 10Hz to 100kHz.
    • Use bypass capacitors to further reduce ripple if necessary.
  8. Thermal Shutdown:

    • The device will shut down if the junction temperature exceeds 160°C to prevent damage.
    • Ensure adequate heat sinking or cooling to keep the device within the operating temperature range.
  9. Operating Temperature:

    • The operating junction temperature range is from -40°C to 125°C.
    • Ensure the device is used within this range to avoid thermal issues.
  10. Capacitor Selection:

    • Use ceramic capacitors with low ESR for input and output filtering.
    • Typical values are 10μF for input and 10μF for output, but these can be adjusted based on specific application requirements.
(For reference only)

View more about TC962CPA on main site