ADC124S021CIMM
Specifications
Details
BUY ADC124S021CIMM https://www.utsource.net/itm/p/12532944.html
Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
---|---|---|---|---|---|---|
Supply Voltage | VDD | Operating | 2.7 | - | 5.5 | V |
Analog Input Voltage | VIN | Operating | 0 | - | VDD | V |
Digital Output Levels | VDOUT | High Level | - | - | VDD-0.3 | V |
Low Level | 0 | - | 0.3 | V | ||
Sampling Rate | fSAMP | - | 200 | - | kSPS | |
Resolution | - | 12 | - | bits | ||
Power Consumption | IDD | Active Mode | - | 1.9 | - | mA |
IDD | Shutdown Mode | - | 1 | - | μA | |
Differential Nonlinearity | DNL | -1 | - | +1 | LSB | |
Integral Nonlinearity | INL | -1 | - | +1 | LSB | |
Signal-to-Noise Ratio | SNR | - | 84 | - | dB |
Instructions for ADC124S021CIMM
Power Supply:
- Connect the supply voltage (VDD) to a stable power source between 2.7V and 5.5V.
- Ensure that the ground (GND) is properly connected.
Analog Input:
- Apply the analog signal to the analog input pin (VIN). The voltage should be within the range of 0V to VDD.
Digital Output Configuration:
- Configure the digital output levels according to the supply voltage. Ensure the high level does not exceed VDD-0.3V and the low level does not exceed 0.3V.
Sampling:
- Set the sampling rate up to 200 kSPS as required by your application.
Power Management:
- For active mode, ensure the power consumption does not exceed 1.9mA.
- To enter shutdown mode, set the appropriate control signal which reduces power consumption to approximately 1μA.
Linearity:
- Verify that the differential nonlinearity (DNL) and integral nonlinearity (INL) are within ±1 LSB for accurate conversions.
Signal Quality:
- Monitor the signal-to-noise ratio (SNR), which typically operates around 84 dB for optimal performance.
Initialization:
- Before starting conversion, initialize the device by setting up the necessary configuration registers via the SPI interface.
Data Conversion:
- Trigger the conversion process either through software command or hardware signal as specified in the datasheet.
Reading Data:
- After conversion, read the data from the digital output pins using the SPI interface.
Ensure all connections are secure and follow the manufacturer’s guidelines for optimal performance.
(For reference only)View more about ADC124S021CIMM on main site