Parameter Symbol Min Typ Max Unit Description
Input Voltage VIN 85 - 265 VAC Operating input voltage range
Output Power POUT - 6 - W Maximum output power
Quiescent Current IQ - 3.5 - mA Quiescent current at no load
Start-Up Current ISTART - 1.5 - mA Initial start-up current
Operating Frequency fSW 65 - 132 kHz Switching frequency range
Minimum ON Time tON(min) - 120 - ns Minimum on-time
Maximum Duty Cycle DMAX - 0.7 - Maximum duty cycle
Thermal Shutdown TSD - 160 - °C Thermal shutdown temperature
Package Type - - PG - - Package type
Operating Temperature TOPR -40 - 125 °C Operating temperature range
Storage Temperature TSTG -40 - 150 °C Storage temperature range

Instructions for Using LNK606PG

  1. Input Voltage:

    • Ensure the input voltage is within the specified range (85VAC to 265VAC) to avoid damage to the device.
  2. Output Power:

    • The maximum output power is 6W. Design your circuit to not exceed this limit to ensure reliable operation.
  3. Quiescent Current:

    • The quiescent current is 3.5mA at no load. This should be considered when calculating the overall efficiency of your power supply.
  4. Start-Up Current:

    • The initial start-up current is 1.5mA. This is important for designing the power-on sequence and ensuring that the device starts reliably.
  5. Operating Frequency:

    • The switching frequency ranges from 65kHz to 132kHz. This should be considered when designing the filter and transformer components.
  6. Minimum ON Time:

    • The minimum on-time is 120ns. This affects the design of the control loop and the selection of external components.
  7. Maximum Duty Cycle:

    • The maximum duty cycle is 0.7 (70%). This should be taken into account when designing the power stage to prevent overloading.
  8. Thermal Shutdown:

    • The device will shut down if the temperature exceeds 160°C. Ensure proper heat dissipation and cooling to prevent thermal shutdown.
  9. Package Type:

    • The LNK606PG is available in a PG package. Follow the recommended PCB layout and soldering guidelines to ensure reliable mounting.
  10. Operating Temperature:

    • The operating temperature range is -40°C to 125°C. Ensure that the device operates within this range to avoid performance degradation or failure.
  11. Storage Temperature:

    • The storage temperature range is -40°C to 150°C. Store the device in a controlled environment to prevent damage.
  12. Handling:

    • Handle the device with care to avoid static discharge, which can damage the internal components. Use ESD protection measures during handling and assembly.
(For reference only)

View more about LNK606PG on main site