Parameter | Symbol | Min | Typ | Max | Unit | Description |
---|---|---|---|---|---|---|
Input Voltage | VIN | 85 | - | 265 | VAC | Operating input voltage range |
Output Power | POUT | - | 6 | - | W | Maximum output power |
Quiescent Current | IQ | - | 3.5 | - | mA | Quiescent current at no load |
Start-Up Current | ISTART | - | 1.5 | - | mA | Initial start-up current |
Operating Frequency | fSW | 65 | - | 132 | kHz | Switching frequency range |
Minimum ON Time | tON(min) | - | 120 | - | ns | Minimum on-time |
Maximum Duty Cycle | DMAX | - | 0.7 | - | Maximum duty cycle | |
Thermal Shutdown | TSD | - | 160 | - | °C | Thermal shutdown temperature |
Package Type | - | - | PG | - | - | Package type |
Operating Temperature | TOPR | -40 | - | 125 | °C | Operating temperature range |
Storage Temperature | TSTG | -40 | - | 150 | °C | Storage temperature range |
Instructions for Using LNK606PG
Input Voltage:
- Ensure the input voltage is within the specified range (85VAC to 265VAC) to avoid damage to the device.
Output Power:
- The maximum output power is 6W. Design your circuit to not exceed this limit to ensure reliable operation.
Quiescent Current:
- The quiescent current is 3.5mA at no load. This should be considered when calculating the overall efficiency of your power supply.
Start-Up Current:
- The initial start-up current is 1.5mA. This is important for designing the power-on sequence and ensuring that the device starts reliably.
Operating Frequency:
- The switching frequency ranges from 65kHz to 132kHz. This should be considered when designing the filter and transformer components.
Minimum ON Time:
- The minimum on-time is 120ns. This affects the design of the control loop and the selection of external components.
Maximum Duty Cycle:
- The maximum duty cycle is 0.7 (70%). This should be taken into account when designing the power stage to prevent overloading.
Thermal Shutdown:
- The device will shut down if the temperature exceeds 160°C. Ensure proper heat dissipation and cooling to prevent thermal shutdown.
Package Type:
- The LNK606PG is available in a PG package. Follow the recommended PCB layout and soldering guidelines to ensure reliable mounting.
Operating Temperature:
- The operating temperature range is -40°C to 125°C. Ensure that the device operates within this range to avoid performance degradation or failure.
Storage Temperature:
- The storage temperature range is -40°C to 150°C. Store the device in a controlled environment to prevent damage.
Handling:
- Handle the device with care to avoid static discharge, which can damage the internal components. Use ESD protection measures during handling and assembly.